ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2024
Optical fiber chemical sensing of anionic surfactants using a microfluidic polymer chip with embedded ion-selective fluorescence optode.
Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study introduces a novel microfluidic polymer chip system that employs an embedded anionic surfactant (AS) ion-selective fluorescence optode (AS fluorescence optode) as a detector for measuring AS. The AS fluorescent optode comprises a lactone form of rhodamine B (L-RB) embedded in 2-nitrophenyl octyl ether plasticized poly (vinyl chloride) membrane. The AS fluorescence optode demonstrated a linear correlation between fluorescence intensity peak heights and AS concentrations within the range of less than 20 µM under optimal flow conditions. The limit of detection for AS was approximately 0.06 µM. The microfluidic system was utilized to measure AS levels in environmental samples, such as river water and tap water.
Indexed as
Identifiers
38643336What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.