Evidence map›Paper›PMID 38637577›Full record

ArticleScientific reports2024

Electrophysiological cardiovascular MR: procedure-ready mesh model generation for interventional guidance based on non-selective excitation compressed sensing whole heart imaging.

Cosima Jahnke, Angeliki Darma, Frank Lindemann, Sabrina Oebel, Sebastian Hilbert, Kerstin Bode, Christian Stehning, Jouke Smink, Ingo Paetsch

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. (Cardiac) complexity needs interaction.Scientific reports · 2025
    Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 3 countries.

Cosima JahnkeDepartment of Electrophysiology, HELIOS Heart Center Leipzig at University of Leipzig, Struempellstr. 39, 04289, Leipzig, Germany.
Angeliki DarmaDepartment of Electrophysiology, HELIOS Heart Center Leipzig at University of Leipzig, Struempellstr. 39, 04289, Leipzig, Germany.
Frank LindemannDepartment of Electrophysiology, HELIOS Heart Center Leipzig at University of Leipzig, Struempellstr. 39, 04289, Leipzig, Germany.
Sabrina OebelDepartment of Electrophysiology, HELIOS Heart Center Leipzig at University of Leipzig, Struempellstr. 39, 04289, Leipzig, Germany.
Sebastian HilbertDepartment of Electrophysiology, HELIOS Heart Center Leipzig at University of Leipzig, Struempellstr. 39, 04289, Leipzig, Germany.
Kerstin BodeDepartment of Electrophysiology, HELIOS Heart Center Leipzig at University of Leipzig, Struempellstr. 39, 04289, Leipzig, Germany.
Christian StehningPhilips Research Laboratories, Hamburg, Germany.
Jouke SminkPhilips Research Laboratories, Best, The Netherlands.
Ingo PaetschDepartment of Electrophysiology, HELIOS Heart Center Leipzig at University of Leipzig, Struempellstr. 39, 04289, Leipzig, Germany. ingo.paetsch@icloud.com.ORCID 0000-0002-3528-7174
Leipzig Heart Institute · DEPhilips (Finland) · FIPhilips (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fully CMR-guided electrophysiological interventions (EP-CMR) have recently been introduced but data on the optimal CMR imaging protocol are scarce. This study determined the clinical utility of 3D non-selective whole heart steady-state free precession imaging using compressed SENSE (nsWHcs) for automatic segmentation of cardiac cavities as the basis for targeted catheter navigation during EP-CMR cavo-tricuspid isthmus ablation. Fourty-two consecutive patients with isthmus-dependent right atrial flutter underwent EP-CMR radiofrequency ablations. nsWHcs succeeded in all patients (nominal scan duration, 98 ± 10 s); automatic segmentation/generation of surface meshes of right-sided cavities exhibited short computation times (16 ± 3 s) with correct delineation of right atrium, right ventricle, tricuspid annulus and coronary sinus ostium in 100%, 100%, 100% and 95%, respectively. Point-by-point ablation adhered to the predefined isthmus line in 62% of patients (26/42); activation mapping confirmed complete bidirectional isthmus block (conduction time difference, 136 ± 28 ms). nsWHcs ensured automatic and reliable 3D segmentation of targeted endoluminal cavities, multiplanar reformatting and image fusion (e.g. activation time measurements) and represented the basis for precise real-time active catheter navigation during EP-CMR ablations of isthmus-dependent right atrial flutter. Hence, nsWHcs can be considered a key component in order to advance EP-CMR towards the ultimate goal of targeted substrate-based ablation procedures.

Indexed as

Atrial FlutterCatheter AblationArrhythmias, CardiacHeart AtriaHumansSurgical MeshTreatment OutcomeCardiovascular magnetic resonance imagingCMR-guided interventionCompressed SENSEEP-CMRIsthmus-dependent atrial flutterNon-selective SSFPRadiofrequency ablationWhole heart imaging

Identifiers

PMID38637577
PMCPMC11026457
OpenAlexW4394914890

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.