ArticleJournal of neurointerventional surgery2025
Can micro-guidewire advancement forces predict clot consistency and location to assist the first-line technique for mechanical thrombectomy?
Article in Journal of neurointerventional surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Potential of Guidewire-Clot Interaction Forces for Clot Detection in Robotic Mechanical Thrombectomy.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe identification of specific clot characteristics before mechanical thrombectomy (MTB) might allow the selection of the most effective first-line technique, thus potentially improving the procedural outcome. We aimed to evaluate if the microwire push forces could extrapolate information on clot consistency and extension before MTB, based on clot mechanical properties.
methodsWe measured in vitro the forces exerted on the proximal extremity of the guidewire during the advancement and retrieval of the guidewire through clot analogs of different compositions. In addition, we analyzed the forces exerted on the guidewire to extrapolate information about the location of the proximal and distal extremities of the clot analogs.
resultsThe maximum forces recorded during the whole penetration phase were significantly different for hard and soft clots (median values, 55.6 mN vs 15.4 mN, respectively; P<0.0001). The maximum slope of the force curves recorded during the advancement of the guidewire for the first 3 s of penetration also significantly differentiated soft from hard clot analogs (7.6 mN/s vs 23.9 mN/s, respectively; P<0.0001). In addition, the qualitative analysis of the shape of the force curves obtained during the advancement and retrieval of the guidewire showed a good potential for the identification of the proximal and distal edges of the clot analogs.
conclusionOur results demonstrated that it was possible to differentiate between soft and hard clot analogs. Furthermore, force measurements could give important information about the location of the clot extremities. Such an approach might support the selection of the first-line MTB technique, with the potential to improve the outcome.