Evidence map›Paper›PMID 38634981›Full record

ArticlePhysical and engineering sciences in medicine2024

Study of PRESAGE® dosimeter for end-to-end 3D radiotherapy verification using an anthropomorphic phantom with bespoke dosimeter insert.

Muhammad Zamir Mohyedin, Hafiz Mohd Zin, Auwal Abubakar, Ahmad Taufek Abdul Rahman

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Advancements in Tissue-Equivalent Gel Dosimeters.Gels (Basel, Switzerland) · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Muhammad Zamir MohyedinSchool of Physics and Material Studies, Faculty of Applied Sciences, Universiti Teknologi MARA, 40450, Shah Alam, Selangor, Malaysia.
Hafiz Mohd ZinAdvanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, 13700, Kepala Batas, Penang, Malaysia. hafiz.zin@usm.my.ORCID http://orcid.org/0000-0002-5679-7210
Auwal AbubakarAdvanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, 13700, Kepala Batas, Penang, Malaysia.
Ahmad Taufek Abdul RahmanSchool of Physics and Material Studies, Faculty of Applied Sciences, Universiti Teknologi MARA, 40450, Shah Alam, Selangor, Malaysia. ahmadtaufek@uitm.edu.my.
Universiti Sains Malaysia · MYUniversiti Teknologi MARA · MYUniversiti Teknologi MARA System · MY

Funding

Ministry of Higher Education Malaysia 600-IRMI/FRGS 5/3 (412/2019
6 · The paper itself

Abstract

Modern radiotherapy techniques have advanced and become more sophisticated. End-to-end 3D verification of the complex radiotherapy dose distribution in an anthropomorphic phantom can ensure the accuracy of the treatment delivery. The phantoms commonly used for dosimetry are homogeneous solid water phantom which lacks the capability to measure the 3D dose distribution for heterogeneous tissues necessary for advanced radiotherapy techniques. Therefore, we developed an end-to-end 3D radiotherapy dose verification system based on MAX-HD anthropomorphic phantom (Integrated Medical Technologies Inc., Troy, New York) with bespoke intracranial insert for PRESAGE® dosimeter. In this study, several advanced radiotherapy treatment techniques of various levels of complexity; 3D-CRT, IMRT and VMAT treatment, were planned for a 20 mm diameter of a spherical target in the brain region and delivered to the phantom. The dosimeters were read out using an in-house developed optical computed tomography (OCT) imaging system known as 3DmicroHD-OCT. It was found that the measured dose distribution of the PRESAGE® when compared with the measured dose distribution of EBT film and Monaco TPS has a maximum difference of less than 3% for 3D-CRT, IMRT and VMAT treatment plans. The gamma analysis results of PRESAGE® in comparison to EBT film and Monaco TPS show pass rates of more than 95% for the criteria of 3% dose difference and 3 mm distance-to-agreement. This study proves the capability of PRESAGE® and bespoke MAX-HD phantom in conjunction with the 3DmicroHD-OCT system to measure 3D dose distribution for end-to-end dosimetry verification.

Indexed as

Phantoms, ImagingRadiometryRadiotherapy DosageHumansImaging, Three-DimensionalRadiation DosimetersRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedAnthropomorphic phantomEnd-to-endRadiotherapy verification

Identifiers

PMID38634981
OpenAlexW4394921362

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.