Evidence map›Paper›PMID 38633848›Full record

ArticleInfectious diseases & clinical microbiology2023

Development of a Nanoplate-Based Digital PCR Test Method for Quantitative Detection of Human Adenovirus DNA.

Yağmur Eylül Doğantürk, Aylin Dağ-Güzel, Mert Ahmet Kuşkucu

Open access · hybridAbstract read
In one paragraph

Article in Infectious diseases & clinical microbiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

Yağmur Eylül DoğantürkDepartment of Medical Microbiology, İstanbul University-Cerrahpaşa School of Medicine, İstanbul, Türkiye.ORCID https://orcid.org/0000-0001-5034-2058
Aylin Dağ-GüzelDepartment of Medical Microbiology, İstanbul University-Cerrahpaşa School of Medicine, İstanbul, Türkiye.ORCID https://orcid.org/0000-0002-5774-9712
Mert Ahmet KuşkucuDepartment of Medical Microbiology, İstanbul University-Cerrahpaşa School of Medicine, İstanbul, Türkiye.ORCID https://orcid.org/0000-0001-8735-5725
Istanbul Aydın University · TRIstanbul University-Cerrahpaşa · TRKoç University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Digital polymerase chain reaction (dPCR) assay is an advanced PCR technique that allows for the simultaneous detection and absolute quantification of diverse pathogens.Commercially validated kits available for detecting all subtypes of human adenovirus (HAdV) are limited. This study aimed to demonstrate the development of an in-house nanoplate-based dPCR assay with high sensitivity, even at low copy numbers. Materials and Methods: In this methodological study, the standardized HAdV DNA was prepared by amplifying the specific hexon gene region with real-time PCR and purifying the HAdV DNA using magnetic beads from HAdV-positive extractions. Dilutions were tested in triplicate during three independent runs to determine the dynamic range, the limit of detection (LoD), the limit of quantification (LoQ), precision, and reproducibility. The primer and probe sequences used in the study were selected based on a literature review to ensure the detection of all HAdV serotypes in a single run. The selected primers were verified using the US National Center for Biotechnology Information (NBCI) nBLAST tools, and the target sequence was determined using the BioEdit software. The DNA concentration of the stock solution was measured using a Qubit fluorometer. The estimated copy number of the stock solution per milliliter was calculated based on the length of the amplified base sequence and fluorometer measurement. Results: The dynamic range of the test was determined to be from 770.4 to 0.9476 cp/μl, with the LoD and LoQ values both being 0.9476 cp/μl. The coefficient of determination (r Conclusion: The results demonstrated that the dPCR method could be an ideal tool for the diagnosis and absolute quantification of human adenoviruses, especially in low copy numbers. In order to determine the reproducibility of the test and validate the method for field use, it needs to be developed and adapted in various laboratories and supported by clinical studies.

Indexed as

adenovirusdPCRHAdVPCRvalidation

Identifiers

PMID38633848
PMCPMC10986707
OpenAlexW4390604949

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.