Evidence map›Paper›PMID 38633820›Full record

ArticleGE Portuguese journal of gastroenterology2024

Quality Standards in Upper Gastrointestinal Endoscopy: Can Deep Sedation Influence It?

Catarina Correia, Nuno Almeida, Raquel Andrade, Mariana Sant'Anna, Cláudia Macedo, David Perdigoto, Carlos Gregório, Pedro Narra Figueiredo

Abstract read
In one paragraph

Article in GE Portuguese journal of gastroenterology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Catarina CorreiaGastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal.
Nuno AlmeidaGastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal.
Raquel AndradeFaculty of Medicine, University of Coimbra, Coimbra, Portugal.
Mariana Sant'AnnaGastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal.
Cláudia MacedoGastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal.
David PerdigotoGastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal.
Carlos GregórioGastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal.
Pedro Narra FigueiredoGastroenterology Department, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: According to the guideline published by ESGE/UEG, a high-quality esophagogastroduodenoscopy (EGD) implies the application of some criteria that enable better healthcare outcomes. Although intra-procedural performance measures are dependent on patient factors, there is no reference to sedation practices in the guideline mentioned above. Objective: This study aimed to evaluate whether deep sedation influences EGD performance measures established by ESGE/UEG. Methods: This was a cross-sectional study, with a prospective enrollment, that considered for inclusion consecutive patients referred for EGD. Two questionnaires were used to assess performance measures and patient satisfaction after EGD. Results: Sedation had a statistically significant impact on most quality indicators, including complete examination (77.2% without sedation vs. 97.8% with sedation), inspection time (6.17 ± 3.45 vs. 8.39 ± 2.67 min), photodocumentation (78% vs. 97.8%), biopsies (39.3% vs. 60.7%), and patient satisfaction (5.42 ± 2.93 vs. 9.1 ± 1.19). The main reason for an incomplete procedure was patient intolerance (82.6%). Discussion: Deep sedation of patients submitted to EGD proved to be a determinant in the applicability of the ESGE/UEG quality indicators. Patient intolerance was eliminated in the group with sedation, enhancing procedure completeness, adequate pathology identification, management, and consequently, the effectiveness of the exam. Conclusion: Sedation administration should be considered in patients undergoing EGD since it ensures a high-quality procedure.

Indexed as

Quality standardsSedationUpper gastrointestinal endoscopy

Identifiers

PMID38633820
PMCPMC11021818

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked