Evidence map›Paper›PMID 38633060›Full record

ArticleBiomedical optics express2024

Dual modality intravascular catheter system combining pulse-sampling fluorescence lifetime imaging and polarization-sensitive optical coherence tomography.

Julien Bec, Xiangnan Zhou, Martin Villiger, Jeffrey A Southard, Brett Bouma, Laura Marcu

Abstract read
In one paragraph

Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Julien BecBiomedical Engineering, University of California, Davis, CA 95616, USA.ORCID https://orcid.org/0000-0003-1222-4071
Xiangnan ZhouBiomedical Engineering, University of California, Davis, CA 95616, USA.ORCID https://orcid.org/0000-0002-6715-5176
Martin VilligerWellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.ORCID https://orcid.org/0000-0003-3819-1271
Jeffrey A SouthardDivision of Cardiovascular Medicine, UC Davis Health System, University of California-Davis, Sacramento, CA 95817, USA.
Brett BoumaWellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Laura MarcuBiomedical Engineering, University of California, Davis, CA 95616, USA.ORCID https://orcid.org/0000-0003-2369-0748

Funding

TRD3: Percutaneous and Interstitial ImagingP41EB015903 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Jacqueline Namati · 2012 to 2026
$22.4M
TRD3: Data Analytics and Intelligent Systems (AI-ML-DL-Visualization)P41EB032840 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI Griffith R. Harsh · 2022 to 2026
$6.7M
Dual-modality FLIm and PSOCT for intravascular imaging of plaque in patientsR01HL157712 · NHLBI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI BOUMA, BRETT E, MARCU, LAURA · 2021 to 2025
$3.4M
NHLBI NIH HHS R01 HL157712NIBIB NIH HHS P41 EB015903NIBIB NIH HHS P41 EB032840
6 · The paper itself

Abstract

The clinical management of coronary artery disease and the prevention of acute coronary syndromes require knowledge of the underlying atherosclerotic plaque pathobiology. Hybrid imaging modalities capable of comprehensive assessment of biochemical and morphological plaques features can address this need. Here we report the first implementation of an intravascular catheter system combining fluorescence lifetime imaging (FLIm) with polarization-sensitive optical coherence tomography (PSOCT). This system provides multi-scale assessment of plaque structure and composition via high spatial resolution morphology from OCT, polarimetry-derived tissue microstructure, and biochemical composition from FLIm, without requiring any molecular contrast agent. This result was achieved with a low profile (2.7 Fr) double-clad fiber (DCF) catheter and high speed (100 fps B-scan rate, 40 mm/s pullback speed) console. Use of a DCF and broadband rotary junction required extensive optimization to mitigate the reduction in OCT performance originating from additional reflections and multipath artifacts. This challenge was addressed by the development of a broad-band (UV-visible-IR), high return loss (47 dB) rotary junction. We demonstrate in phantoms,

Identifiers

PMID38633060
PMCPMC11019710

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.