ArticleMedical physics2024
High-resolution 3T to 7T ADC map synthesis with a hybrid CNN-transformer model.
Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- An efficient 3D latent diffusion model for T1-contrast enhanced MRI generation.Biomedical physics & engineering express · 2026Article
- Comparison of reduced FOV diffusion-weighted imaging of rectal cancer at 5.0T ultra-high field versus 3.0T MRI: image quality and histopathological T staging.BMC medical imaging · 2025Article
- Res-MoCoDiff: residual-guided diffusion models for motion artifact correction in brain MRI.Physics in medicine and biology · 2025Article
- Systematic Review and Meta-analysis of AI-driven MRI Motion Artifact Detection and Correction.ArXiv · 2025Article
- Res-MoCoDiff: Residual-guided diffusion models for motion artifact correction in brain MRI.ArXiv · 2025Article
- Deep learning based apparent diffusion coefficient map generation from multi-parametric MR images for patients with diffuse gliomas.Medical physics · 2025Article
- Advancing MRI Reconstruction: A Systematic Review of Deep Learning and Compressed Sensing Integration.ArXiv · 2025Article
- Fast MRI Reconstruction Using Deep Learning-based Compressed Sensing: A Systematic Review.ArXiv · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
background7 Tesla (7T) apparent diffusion coefficient (ADC) maps derived from diffusion-weighted imaging (DWI) demonstrate improved image quality and spatial resolution over 3 Tesla (3T) ADC maps. However, 7T magnetic resonance imaging (MRI) currently suffers from limited clinical unavailability, higher cost, and increased susceptibility to artifacts. PURPOSE: To address these issues, we propose a hybrid CNN-transformer model to synthesize high-resolution 7T ADC maps from multimodal 3T MRI.
methodsThe Vision CNN-Transformer (VCT), composed of both Vision Transformer (ViT) blocks and convolutional layers, is proposed to produce high-resolution synthetic 7T ADC maps from 3T ADC maps and 3T T1-weighted (T1w) MRI. ViT blocks enabled global image context while convolutional layers efficiently captured fine detail. The VCT model was validated on the publicly available Human Connectome Project Young Adult dataset, comprising 3T T1w, 3T DWI, and 7T DWI brain scans. The Diffusion Imaging in Python library was used to compute ADC maps from the DWI scans. A total of 171 patient cases were randomly divided into 130 training cases, 20 validation cases, and 21 test cases. The synthetic ADC maps were evaluated by comparing their similarity to the ground truth volumes with the following metrics: peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), and mean squared error (MSE). In addition,
resultsThe results are as follows: PSNR: 27.0 ± 0.9 dB, SSIM: 0.945 ± 0.010, and MSE: 2.0E-3 ± 0.4E-3. Both qualitative and quantitative results demonstrate that VCT performs favorably against other state-of-the-art methods. We have introduced various efficiency improvements, including the implementation of flash attention and training on 176×208 resolution images. These enhancements have resulted in the reduction of parameters and training time per epoch by 50% in comparison to ResViT. Specifically, the training time per epoch has been shortened from 7.67 min to 3.86 min.
conclusionWe propose a novel method to predict high-resolution 7T ADC maps from low-resolution 3T ADC maps and T1w MRI. Our predicted images demonstrate better spatial resolution and contrast compared to 3T MRI and prediction results made by ResViT and pix2pix. These high-quality synthetic 7T MR images could be beneficial for disease diagnosis and intervention, producing higher resolution and conformal contours, and as an intermediate step in generating synthetic CT for radiation therapy, especially when 7T MRI scanners are unavailable.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.