Evidence map›Paper›PMID 38628729›Full record

ArticleHeliyon2024

Effect of structural support size and position on depressed tibial plateau fractures: A finite element analysis.

Xiaomeng Ren, Cheng Xu, Yu Jiang, Da Teng, Xinmo Liu, Junsong Wang, Wei Zhang

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 93% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. [Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Xiaomeng RenSenior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, 51 Fucheng Road, Haidian District, Beijing, 100089, China.
Cheng XuSenior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, 51 Fucheng Road, Haidian District, Beijing, 100089, China.
Yu JiangSenior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, 51 Fucheng Road, Haidian District, Beijing, 100089, China.
Da TengSenior Department of General Surgery, The First Medical Center of Chinese PLA General Hospital, 28 Fuxing Road, Haidian District, Beijing, 100089, China.
Xinmo LiuSenior Department of General Surgery, The First Medical Center of Chinese PLA General Hospital, 28 Fuxing Road, Haidian District, Beijing, 100089, China.
Junsong WangSenior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, 51 Fucheng Road, Haidian District, Beijing, 100089, China.
Wei ZhangSenior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, 51 Fucheng Road, Haidian District, Beijing, 100089, China.
Chinese PLA General Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Structural support for depressed tibial plateau fractures is receiving increasing attention. Currently, there has been little biomechanical evaluation of structural support. This work aimed to investigate the effect of structural support size and position on fracture fixation stability. Methods: A split-depressed tibial plateau fracture model was created according to the fracture map. Cortical screws combined with structural filler were used for fracture fixation. The filler diameter was set to small, medium and large, and the filler position was set to the center and offset by 1, 2 and 3 mm to study the effect of position and size on stability. Results: The maximum stress on the implant in all scenarios occurs at the lower contact surface between the anterior screw and the filler. Increased support size resulted in increased mean maximum screw stress, depressed fragment axial displacement and separated fragment transverse displacement (screw stress: 266.6 ± 37.7 MPa vs. 266.7 ± 51.0 MPa vs. 273.8 ± 41.5 MPa; depressed displacement: 0.123 ± 0.036 mm vs. 0.133 ± 0.049 mm vs. 0.158 ± 0.050 mm; separated displacement: 0.402 ± 0.031 mm VS 0.412 ± 0.047 mm VS 0.437 ± 0.049 mm). The larger the offset of the support position was, the larger the peak screw stress and the larger the reduction loss of depressed and separated fragment reduction, regardless of the support size. The medium support combined with the central position presented the minimum of peak stress and reduction loss. Cortical bone was below 2 % and trabecular strain was below 10 % for all scenarios. Conclusion: Central placement of structural support provides superior stability for the treatment of depressed tibial plateau fractures compared to the eccentric placement. When a support is placed centrally, optimal stability is achieved when the diameter matches the diameter of the depressed region. Thus, the utilization of equal-diameter fillers to provide central support appears to be an ideal selection for depressed tibial plateau fractures.

Indexed as

Bone graftDepressed tibial plateau fractureFinite element analysisInternal fixationStructural support

Identifiers

PMID38628729
PMCPMC11019227
OpenAlexW4394692868

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.