Evidence map›Paper›PMID 38628531›Full record

ArticleSurgical neurology international2024

Successful shrinkage of a recurrent partially thrombosed symptomatic large basilar tip aneurysm using a Target 3D Coil.

Noriaki Ashida, Atsushi Fujita, Hideya Hayashi, Masashi Higashino, Yusuke Ikeuchi, Hirofumi Iwahashi, Masamitsu Nishihara, Kohkichi Hosoda, Takashi Sasayama

Open access · hybridAbstract readCase Reports
In one paragraph

Article in Surgical neurology international, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Noriaki AshidaDepartment of Neurosurgery, Kobe City Nishi-Kobe Medical Center, Kobe, Japan.
Atsushi FujitaDepartment of Neurosurgery, Graduate School of Medicine, Kobe University, Kobe, Japan.
Hideya HayashiDepartment of Neurosurgery, Kobe City Nishi-Kobe Medical Center, Kobe, Japan.
Masashi HigashinoDepartment of Neurosurgery, Jyunshin Hospital, Kakogawa, Japan.
Yusuke IkeuchiDepartment of Neurosurgery, Graduate School of Medicine, Kobe University, Kobe, Japan.
Hirofumi IwahashiDepartment of Neurosurgery, Kobe City Nishi-Kobe Medical Center, Kobe, Japan.
Masamitsu NishiharaDepartment of Neurosurgery, Kobe City Nishi-Kobe Medical Center, Kobe, Japan.
Kohkichi HosodaDepartment of Neurosurgery, Myodani Hospital, Kobe, Japan.
Takashi SasayamaDepartment of Neurosurgery, Graduate School of Medicine, Kobe University, Kobe, Japan.
Kobe City Nishi-Kobe Medical Center · JPKobe University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Standalone coil embolization is often less effective for partially thrombosed intracerebral aneurysms (PTIA) because of the risk of frequent recurrence if the coil migrates into the thrombus. This report describes a case of PTIA at the basilar tip in which simple coil embolization using a Target 3D Coil resulted in sustained remission without recurrence during long-term follow-up. Case Description: The patient was a 63-year-old male who presented with right oculomotor nerve palsy after having undergone direct surgery for a basilar artery aneurysm 15 years earlier. Recurrence with partial thrombosis of the basilar artery aneurysm was diagnosed. Target 3D Coil embolization with frame construction in the aneurysmal sac was performed, resulting in the complete disappearance of the aneurysm and improvement of the oculomotor nerve palsy. Magnetic resonance imaging at five years postoperatively confirmed that the thrombus had completely disappeared, and there was no recurrence of the aneurysm. The closed loops in the Target 3D Coil may have contributed to the cohesive mass of coils remaining in the sac of the PTIA, potentially leading to healing. Conclusion: The characteristics of the Target 3D Coil may have prevented migration of the coil into the thrombus, potentially contributing to the successful resolution of the aneurysm.

Indexed as

Coil embolizationPartially thrombosed intracranial aneurysmTarget 3D Coil

Identifiers

PMID38628531
PMCPMC11021097
OpenAlexW4393093415

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.