Evidence map›Paper›PMID 38625764›Full record

ArticleIEEE transactions on bio-medical engineering2024

Nonlinear Viscoelastic Modeling of Finger Arteries: Toward Smartphone-Based Blood Pressure Monitoring via the Oscillometric Finger Pressing Method.

Cederick Landry, Mark Freithaler, Vishaal Dhamotharan, Hadi Daher, Sanjeev G Shroff, Ramakrishna Mukkamala

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Cederick Landry
Mark Freithaler
Vishaal Dhamotharan
Hadi Daher
Sanjeev G Shroff
Ramakrishna Mukkamala
University of Pittsburgh · US

Funding

Cardiovascular Bioengineering Training ProgramT32HL076124 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI SANJEEV G SHROFF · 2005 to 2026
$7.0M
A Smartphone-Based Device for Cuff-Less and Calibration-Free Blood Pressure MonitoringR01HL146470 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI MUKKAMALA, RAMAKRISHNA · 2019 to 2022
$1.1M
NHLBI NIH HHS R01 HL146470NHLBI NIH HHS T32 HL076124
6 · The paper itself

Abstract

objectiveOscillometric finger pressing is a smartphone-based blood pressure (BP) monitoring method. Finger photoplethysmography (PPG) oscillations and pressure are measured during a steady increase in finger pressure, and an algorithm computes systolic BP (SP) and diastolic BP (DP) from the measurements. The objective was to assess the impact of finger artery viscoelasticity on the BP computation.

methodsNonlinear viscoelastic models relating transmural pressure (finger BP - applied pressure) to PPG oscillations during finger pressing were developed. The output of each model to a measured transmural pressure input was fitted to measured PPG oscillations from 15 participants. A parametric sensitivity analysis was performed via model simulations to elucidate the viscoelastic effect on the derivative-based BP computation algorithm.

resultsA Wiener viscoelastic model comprising a first-order transfer function followed by a static sigmoidal function fitted the measured PPG oscillations better than an elastic model containing only the static function (median (IQR) error of 30.5% (25.6%-34.0%) vs 50.9% (46.7%-53.7%); p<0.01). In Wiener model simulations, the derivative algorithm underestimated SP, especially with high pulse pressure and low transfer function cutoff frequency (i.e., greater viscoelasticity). The mean of the normalized PPG waveform at the maximum oscillation beat was found to correlate with the cutoff frequency (r = -0.8) and could thus possibly be used to compensate for viscoelasticity.

conclusionFinger artery viscoelasticity negatively impacts oscillometric BP computation algorithms but can potentially be compensated for using available measurements. SIGNIFICANCE: These findings may help in converting smartphones into truly cuffless BP monitors for improving hypertension awareness and control.

Indexed as

ArteriesBlood Pressure DeterminationFingersModels, CardiovascularPhotoplethysmographySmartphoneAdultAlgorithmsBlood PressureElasticityFemaleHumansMaleNonlinear DynamicsOscillometrySignal Processing, Computer-Assisted

Identifiers

PMID38625764
PMCPMC11389602
OpenAlexW4394841748

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.