Evidence map›Paper›PMID 38624354›Full record

ArticleNpj flexible electronics2020

A tailored, electronic textile conformable suit for large-scale spatiotemporal physiological sensing in vivo.

Irmandy Wicaksono, Carson I Tucker, Tao Sun, Cesar A Guerrero, Clare Liu, Wesley M Woo, Eric J Pence, Canan Dagdeviren

Abstract read
In one paragraph

Article in Npj flexible electronics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 43 papers.

0numbers the graph read from it
0cells of the map it votes in
43citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

43 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. [Research progress on flexible wearable sensors for health monitoring].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Review
  7. Unperceivable Designs of Wearable Electronics.Advanced materials (Deerfield Beach, Fla.) · 2025
    Review
  8. Article
  9. Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Review
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Irmandy WicaksonoMedia Lab, Massachusetts Institute of Technology, Cambridge, 02139 MA USA.
Carson I TuckerMechanical Engineering, Massachusetts Institute of Technology, Cambridge, 02139 MA USA.
Tao SunMedia Lab, Massachusetts Institute of Technology, Cambridge, 02139 MA USA.
Cesar A GuerreroElectrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, 02142 MA USA.
Clare LiuElectrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, 02142 MA USA.
Wesley M WooElectrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, 02142 MA USA.
Eric J PenceElectrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, 02142 MA USA.ORCID 0000-0003-0775-1707
Canan DagdevirenMedia Lab, Massachusetts Institute of Technology, Cambridge, 02139 MA USA.ORCID 0000-0002-2032-792X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The rapid advancement of electronic devices and fabrication technologies has further promoted the field of wearables and smart textiles. However, most of the current efforts in textile electronics focus on a single modality and cover a small area. Here, we have developed a tailored, electronic textile conformable suit (E-TeCS) to perform large-scale, multimodal physiological (temperature, heart rate, and respiration) sensing in vivo. This platform can be customized for various forms, sizes and functions using standard, accessible and high-throughput textile manufacturing and garment patterning techniques. Similar to a compression shirt, the soft and stretchable nature of the tailored E-TeCS allows intimate contact between electronics and the skin with a pressure value of around ~25 mmHg, allowing for physical comfort and improved precision of sensor readings on skin. The E-TeCS can detect skin temperature with an accuracy of 0.1 °C and a precision of 0.01 °C, as well as heart rate and respiration with a precision of 0.0012 m/s

Indexed as

Electrical and electronic engineeringSensors and probes

Identifiers

PMID38624354
PMCPMC7222957

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.