Evidence map›Paper›PMID 38622241›Full record

ArticleScientific reports2024

Lab on a bead with oscillatory centrifugal microfluidics for fast and complete mixing enables fast and accurate biomedical assays.

David E Williams, Wei Li, Mithileshwari Chandrasekhar, Carsten Ma On Wong Corazza, Gerrit Sjoerd Deijs, Lionel Djoko, Bhavesh Govind, Ellen Jose, Yong Je Kwon, Tiffany Lowe and 4 more

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

David E WilliamsSchool of Chemical Sciences, University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand. david.williams@auckland.ac.nz.
Wei LiOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Mithileshwari ChandrasekharOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Carsten Ma On Wong CorazzaOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Gerrit Sjoerd DeijsOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Lionel DjokoOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Bhavesh GovindOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Ellen JoseOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Yong Je KwonOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Tiffany LoweOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Anil PanchalOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Gabrielle ReshefOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
Matheus J T VargasOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand.
M Cather SimpsonOrbis Diagnostics Ltd, 14 West St, Eden Terrace, Auckland, 1010, New Zealand. c.simpson@auckland.ac.nz.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rapid mixing and precise timing are key for accurate biomedical assay measurement, particularly when the result is determined as the rate of a reaction: for example rapid immunoassay in which the amount of captured target is kinetically determined; determination of the concentration of an enzyme or enzyme substrate; or as the final stage in any procedure that involves a capture reagent when an enzyme reaction is used as the indicator. Rapid mixing and precise timing are however difficult to achieve in point-of-care devices designed for small sample volumes and fast time to result. By using centrifugal microfluidics and transposing the reaction surface from a chamber to a single mm-scale bead we demonstrate an elegant and easily manufacturable solution. Reagents (which may be, for example, an enzyme, enzyme substrate, antibody or antigen) are immobilised on the surface of a single small bead (typically 1-2 mm in diameter) contained in a cylindrical reaction chamber subjected to periodically changing rotational accelerations which promote both mixing and uniform mass-transfer to the bead surface. The gradient of Euler force across the chamber resulting from rotational acceleration of the disc, dΩ

Indexed as

AntibodiesMicrofluidicsAntigensHydrophobic and Hydrophilic InteractionsPoint-of-Care SystemsAntibodiesAntigens

Identifiers

PMID38622241
PMCPMC11018808

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.