Evidence map›Paper›PMID 38620837›Full record

ArticleIFAC-PapersOnLine2020

A Nonlinear Hysteretic Model for Automated Prediction of Lung Mechanics during Mechanical Ventilation.

Cong Zhou, J Geoffrey Chase, Qianhui Sun, Jennifer Knopp

Abstract read
In one paragraph

Article in IFAC-PapersOnLine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Cong ZhouSchool of Civil Aviation, Northwestern Polytechnical University, China.
J Geoffrey ChaseDepartment of Mechanical Engineering; Dept of Mechanical Eng, Centre for Bio-Engineering, University of Canterbury Christchurch, New Zealand.
Qianhui SunDepartment of Mechanical Engineering; Dept of Mechanical Eng, Centre for Bio-Engineering, University of Canterbury Christchurch, New Zealand.
Jennifer KnoppDepartment of Mechanical Engineering; Dept of Mechanical Eng, Centre for Bio-Engineering, University of Canterbury Christchurch, New Zealand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mechanical ventilation (MV) is core intensive care unit (ICU) therapy during the Covid-19 pandemic. Optimising MV care to a specific patient with respiratory failure is difficult due to inter- and intra- patient variability in lung mechanics and condition. The ability to accurately predict patient-specific lung response to a change in MV settings would enable semi-automated care and significantly improve the efficiency of MV monitoring and care. It has particular emphasis when considering MV care required to treat Covid-19 patients, who require longer MV care, where patient-specific care can reduce the time on MV required. This study develops a nonlinear smooth hysteresis loop model (HLM) able to capture the essential lung dynamics in a patient-specific fashion from measured ventilator data, particularly for changes of compliance and infection points of the pressure-volume loop. The automated (no human input) hysteresis loop analysis (HLA) method is applied to identify HLM model parameters, enabling automated digital cloning to create a virtual patient model to accurately predict lung response at a specified positive end expiratory pressure (PEEP) level, as well as in response to the changes of PEEP. The performance of this automated digital cloning approach is assessed using clinical data from 4 patients and 8 recruitment maneuver (RM) arms. Validation results show the HLM-based hysteresis loops identified using HLA match clinical pressure-volume loops very well with root-mean-square (RMS) errors less than 2% for all 8 data sets over 4 patients, validating the accuracy of the developed HLM in capturing the essential lung physiology and respiratory behaviours at different patient conditions. More importantly, the patient-specific digital clones at lower PEEP levels accurately predict lung response at higher PEEP levels with predicted peak inspiratory pressure (PIP) errors less than 2% in average. In addition, the resulted additional lung volume

Indexed as

Hysteresis loop analysisHysteresis ModelLung mechanicsMechanical VentilationNonlinear ModellingVirtual Patient

Identifiers

PMID38620837
PMCPMC8153200

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked