ArticleEnergy and buildings2023

Optimization-informed Rule Extraction for HVAC system: A Case Study of Dedicated Outdoor Air System Control in a Mixed-Humid Climate Zone.

Youngsik Choi, Xing Lu, Zheng O'Neill, Fan Feng, Tao Yang

Open access · greenAbstract read
In one paragraph

Article in Energy and buildings, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
3.9field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 25 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Youngsik ChoiJ. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University, College Station, TX, United States.
Xing LuJ. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University, College Station, TX, United States.
Zheng O'NeillJ. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University, College Station, TX, United States.
Fan FengJ. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University, College Station, TX, United States.
Tao YangJ. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University, College Station, TX, United States.
Walker (United States) · USPacific Northwest National Laboratory · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the era of post-Coronavirus Disease 2019, the dedicated outdoor air system (DOAS), which provides 100% outdoor air for the building, is widely acknowledged as it can ensure acceptable indoor air quality by delivering fresh outdoor air to occupied space. The DOAS with a proper design and operation can provide sufficient ventilation and dehumidification while achieving energy efficiency. Nonetheless, there is limited guidance in determining the optimal control sequence of the DOAS for the designers and operators to implement in practice. Accordingly, in practice, a number of issues have been acknowledged in the design and control phases of DOAS, including insufficient ventilation and dehumidification, and increasing supply air dry-bulb temperature in fear of over-cooling, which might cause significant discomfort and energy waste. There have been efforts to develop high-performing DOAS controls for better energy efficiency. However, such controls are often complex, or difficult to interpret, for building designers and operators to consider in practice. In this regard, this paper explores a simulation-based framework for generating a supply air temperature control sequence of the DOAS not only to ensure improved energy-saving potential but also to guarantee the implement-ability of the control logic. The U.S Department of Energy prototype primary school with dynamic occupancy profiles was modeled with a whole building simulation program, EnergyPlus. The model consists of a DOAS with an exhaust air energy recovery system for ventilation and fan-coil units for space cooling and heating. Then, a Genetic Algorithm was adopted to find the true optimal supply air temperature control sequence in terms of minimizing the energy cost of the heating, ventilation, and air conditioning system operation. Lastly, Decision Tree was adopted to extract rules out of the optimums to derive an implementable sequence of operation for the DOAS supply air temperature. A total of 12 week-simulation including four weeks of heating, cooling, and shoulder seasons, separately, under the weather condition of New York City was conducted for the case study. This case study identified that the optimization-informed rule extraction-based control, when compared to conventional outdoor air temperature-based reset control, could save about 13% of energy cost and 25% of energy consumption throughout the heating, cooling, and shoulder seasons. It is notable that the energy-saving was mainly achieved by reducing the heating energy consumption. Importantly, it nearly corresponds to the true optimal control result, which reduces approximately 14% of energy cost and 27% of energy consumption. From the results, it can be highlighted that the optimization-informed rule extraction can be as energy effective as the optimal control, while significantly reducing the complexity of the control.

Indexed as

Building energy simulationDedicated Outdoor Air SystemGenetic AlgorithmOptimal controlRule extraction