Evidence map›Paper›PMID 38619791›Full record

ArticleInternational journal of computer assisted radiology and surgery2024

The development and testing of a smart sensorized guide wire for catheterization in a "blood" vessel phantom to support aortic valve implementation.

M Berger, N Kuhn, M Pillei, N Bonaros, T Senfter

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 91% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

M BergerDepartment of Environmental, Process and Energy Engineering, MCI - The Entrepreneurial School, Innsbruck, Austria. manuel.berger@mci.edu.ORCID http://orcid.org/0000-0001-5026-6251
N KuhnDepartment of Medical Technologies, MCI - The Entrepreneurial School, Innsbruck, Austria.
M PilleiDepartment of Environmental, Process and Energy Engineering, MCI - The Entrepreneurial School, Innsbruck, Austria.ORCID http://orcid.org/0000-0003-1459-7234
N BonarosDepartment of Cardiac Surgery, Medical University of Innsbruck, Innsbruck, Austria.ORCID http://orcid.org/0000-0002-7656-5812
T SenfterDepartment of Environmental, Process and Energy Engineering, MCI - The Entrepreneurial School, Innsbruck, Austria.ORCID http://orcid.org/0000-0002-9379-2080
Management Center Innsbruck · ATInnsbruck Medical University · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeHeart valve disease is commonly treated by minimally invasive procedures with guide wires and catheterization. The main purpose of this study is to find out whether an extension of the guide wire with a sensor can support the surgeon within the blood vessel to reduce X-ray necessity.

methodsA smart guide wire is developed by an extension with a flex-bending sensor to evaluate the sensor signal with and without "blood" flow at a constant compression force. Various surgically relevant investigations are performed. For assessment, the mean temporal average of the moving averaged filtered ADC signal and a subsequent FFT are carried out.

resultsResults show that there is a smaller sensor signal when the applied force or bending at the sensor is higher. In all investigations, there was a different sensor signal. The flex-bending sensor can detect the effect of pulsatile flow. The smallest temporal averaged signal difference between reference and clamp in the front wire's tip is 1.09%. For example, the mean temporal average of the filtered ADC signal for different clinically relevant scenarios is between 2550 and 2900.

conclusionsThe results show that the sensorized guide wire developed for catheterization can support aortic valve implementation. The sensor sensitivity is sufficient to detect even very small variations within the blood vessel and therefore is promising to support catheterization heart valve surgeries in future.

Indexed as

Aortic ValveCardiac CatheterizationEquipment DesignPhantoms, ImagingHumans“Blood” vessel phantomDevelopment of a smart sensorized guide wireExperimental data of sensor dataFlex-bending sensor

Identifiers

PMID38619791
OpenAlexW4394819628

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.