ArticleJournal of clinical monitoring and computing2024

Effect of vertical stopcock position on start-up fluid delivery in syringe pumps used for microinfusions.

Markus Weiss, Pedro David Wendel-Garcia, Beate Grass, Maren Kleine-Brueggeney

Open access · hybridAbstract read
In one paragraph

Article in Journal of clinical monitoring and computing, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Markus WeissDepartment of Anesthesia, University Children's Hospital, Steinwiesstrasse 75, 8032, Zurich, Switzerland. markus.weiss@kispi.uzh.ch.
Pedro David Wendel-GarciaDepartment of Intensive Care, University Hospital Zurich and University of Zurich, Zurich, Switzerland.
Beate GrassNewborn Research, Department of Neonatology, University Hospital Zurich and University of Zurich, Zurich, Switzerland.
Maren Kleine-BrueggeneyDepartment of Cardiac Anesthesiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany.
University of Zurich · CHDeutsches Herzzentrum der Charité · DEUniversity Children's Hospital Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this in vitro study was to evaluate the impact of the vertical level of the stopcock connecting the infusion line to the central venous catheter on start-up fluid delivery in microinfusions. Start-up fluid delivery was measured under standardized conditions with the syringe outlet and liquid flow sensors positioned at heart level (0 cm) and exposed to a simulated CVP of 10 mmHg at a set flow rate of 1 ml/h. Flow and intraluminal pressures were measured with the infusion line connected to the stopcock primarily placed at vertical levels of 0 cm, + 30 cm and - 30 cm or primarily placed at 0 cm and secondarily, after connecting the infusion line, displaced to + 30 cm and - 30 cm. Start-up fluid delivery 10 s after opening the stopcock placed at zero level and after opening the stopcock primarily connected at zero level and secondary displaced to vertical levels of + 30 cm and - 30 cm were similar (- 10.52 [- 13.85 to - 7.19] µL; - 8.84 [- 12.34 to - 5.33] µL and - 11.19 [- 13.71 to - 8.67] µL (p = 0.469)). Fluid delivered at 360 s related to 65% (zero level), 71% (+ 30 cm) and 67% (- 30 cm) of calculated infusion volume (p = 0.395). Start-up fluid delivery with the stopcock primarily placed at + 30 cm and - 30 cm resulted in large anterograde and retrograde fluid volumes of 34.39 [33.43 to 35.34] µL and - 24.90 [- 27.79 to - 22.01] µL at 10 s, respectively (p < 0.0001). Fluid delivered with the stopcock primarily placed at + 30 cm and - 30 cm resulted in 140% and 35% of calculated volume at 360 s, respectively (p < 0.0001). Syringe infusion pumps should ideally be connected to the stopcock positioned at heart level in order to minimize the amounts of anterograde and retrograde fluid volumes after opening of the stopcock.

Indexed as

Equipment DesignInfusion PumpsSyringesCatheterization, Central VenousCentral Venous CathetersCentral Venous PressureHumansInfusions, IntravenousPressureInfusionMicroinfusionPositionPumpStart-upSyringe

Identifiers

PMID38619717
PMCPMC11427552
OpenAlexW4394818401

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.