ArticleJournal of dental sciences2024
Effects of diameters of implant and abutment screw on stress distribution within dental implant and alveolar bone: A three-dimensional finite element analysis.
Article in Journal of dental sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.
- Fixture design effects on posterior dental implant stability using finite element analysis (FEA): a systematic review.Head & face medicine · 2025Pooled it
- Biomechanical comparison of titanium and Y-TZP subperiosteal implants in atrophic maxilla: a finite element study.BMC oral health · 2026Article
- [Research progress on three-dimensional finite element analysis for fixed implant restoration of edentulous jaw].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026Review
- The influence of the connector position placing, cement thickness and load direction on biomechanical performance of implant supported mesial cantilever: Finite element analysis.Journal of dental sciences · 2026Article
- Influence of different customized abutment materials on stress distribution of different internal implant-abutment connections: finite element analysis.BMC oral health · 2025Article
- Finite element analysis of the influence of perioral force on alveolar ridge healing in areas missing maxillary anterior teeth.BMC oral health · 2025Article
- Using optimization approach to design dental implant in three types of bone quality - A finite element analysis.Journal of dental sciences · 2025Article
- Advancing 3D Dental Implant Finite Element Analysis: Incorporating Biomimetic Trabecular Bone with Varied Pore Sizes in Voronoi Lattices.Journal of functional biomaterials · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background/purpose: Few studies have investigated the effects of abutment screw diameter in the stress of dental implants and alveolar bones under occlusal forces. In this study, we investigated how variations in implant diameter, abutment screw diameter, and bone condition affect stresses in the abutment screw, implant, and surrounding bone. Materials and methods: Three-dimensional finite element (FE) models were fabricated for dental implants with external hex-type abutments measuring 4 and 5 mm in diameter. The models also included abutment screws measuring 2.0 and 2.5 mm in diameter. Each implant model was integrated with the mandibular bone comprising the cortical bone and four types of cancellous bone. In total, 12 finite element models were generated, subjected to three different occlusal forces, and analyzed using FE software to investigate the stress distribution of dental implant and alveolar bone. Results: Wider implants demonstrated lower stresses in implant and bone compared with standard-diameter implants. The quality of cancellous bone has a minimal impact on the stress values of the implant, abutment screw, and cortical bone. Regardless of occlusal arrangement or quality of cancellous bone, a consistent pattern emerged: larger abutment screw diameters led to increased stress levels on the screws, while the stress levels in both cortical and cancellous bone showed comparatively minor fluctuations. Conclusion: Wider implants tend to have better stress distribution than standard-diameter implants. The potential advantage of augmenting the abutment screw diameter is unfavorable. It may result in elevated stresses in the implant system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials