Evidence map›Paper›PMID 38617770›Full record

ArticleJournal of thoracic disease2024

Comparison of safety and effectiveness of different sheaths in ablation of focal atrial tachycardia: a retrospective study.

Min Xie, Dingming Liu, Ruikun Jia, Yixuan Bai, Juan Chan, Zhongyun Lin, Paul Khairy, Kaijun Cui

Open access · diamondAbstract read
In one paragraph

Article in Journal of thoracic disease, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 94% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Min XieDepartment of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
Dingming LiuDepartment of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
Ruikun JiaDepartment of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
Yixuan BaiDepartment of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
Juan ChanDepartment of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
Zhongyun LinDepartment of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
Paul KhairyElectrophysiology Service, Montreal Heart Institute, Université de Montréal, Montreal, Canada.
Kaijun CuiDepartment of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
West China Hospital of Sichuan University · CNSichuan University · CNMontreal Heart Institute · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: A novel visualized steerable sheath, referred to as the Vizigo sheath, has been utilized in clinical interventions. The objective of this study was to evaluate and contrast the efficacy and safety of the Vizigo sheath with other sheaths in the catheter ablation (CA) for focal atrial tachycardia (FAT). Methods: A retrospective cohort study was conducted on consecutive patients with CA for FAT from March 2019 to February 2022. Objectives were to assess the impact of the Vizigo sheath on acute and long-term ablation success rates, procedural and fluoroscopy times, and contact force (CF). Results: A total of 164 patients, mean age 50±15 years, 97 (59.1%) women, underwent CA of FAT using the Vizigo sheath (N=42), non-visualized steerable sheath (N=36), or other conventional sheath (N=86). Age, sex, body mass index (BMI), presence of hypertension, heart failure, and diabetes mellitus were not significantly different among the three groups. The acute success rate of 94.0% was similar among the three groups. Over a follow-up of 14±2 months, the Vizigo sheath was associated with superior arrhythmia-free survival (88.1%) when compared to non-visualized steerable (69.4%; P=0.04) and other conventional (72.1%, P=0.046) sheaths. Procedural duration, number of ablation lesions, and ablation times were similar among the three groups. However, the Vizigo sheath was associated with lower fluoroscopy times (e.g., 145 Conclusions: The application of Vizigo sheath can improve the long-term success rate of FAT and reduce the radiation exposure of patients and medical staff in our single-center limited sample study. More research may be needed in the future to confirm our findings.

Indexed as

catheter ablation (CA)contact force (CF)fluoroscopy timeFocal atrial tachycardia (FAT)visualized steerable sheath

Identifiers

PMID38617770
PMCPMC11009573
OpenAlexW4393281300

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.