ArticleACS omega2024
Superlative and Selective Sensing of Serotonin in Undiluted Human Serum Using Novel Polystyrene Sulfonate Conductive Polymer.
Article in ACS omega, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In the past 5 years, real-time health monitoring has become ubiquitous with the development of watches and rings that can measure and report on the physiological state. As an extension, real-time biomarker sensors, such as the continuous glucose monitor, are becoming popular for both health and performance monitoring. However, few real-time sensors for biomarkers have been made commercially available; this is primarily due to problems with cost, stability, sensitivity, selectivity, and reproducibility of biosensors. Therefore, simple, robust sensors are needed to expand the number of analytes that can be detected in emerging and existing wearable platforms. To address this need, we present a simple but novel sensing material. In short, we have modified the already popular PEDOT/PSS conductive polymer by completely removing the PEDOT component and thus have fabricated a polystyrene sulfonate (PSS) sensor electrodeposited on a glassy carbon (GC) base (GC-PSS). We demonstrate that coupling the GC-PSS sensor with differential pulse voltammetry creates a sensor capable of the selective and sensitive detection of serotonin. Notably, the GC-PSS sensor has a sensitivity of 179 μA μM
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.