Evidence map›Paper›PMID 38616940›Full record

ReviewPostepy w kardiologii interwencyjnej = Advances in interventional cardiology2024

Percutaneous left atrial appendage closure with the Watchman device: a systematic review.

Jakub Maksym, Marcin Grabowski, Tomasz Mazurek

Open access · goldAbstract readReview
In one paragraph

Review in Postepy w kardiologii interwencyjnej = Advances in interventional cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Incidence and predictors of device-related thrombus after left atrial appendage closure with Watchman device.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Jakub MaksymFirst Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Marcin GrabowskiFirst Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Tomasz MazurekFirst Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Medical University of Warsaw · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Atrial fibrillation (AF) is the most commonly observed arrhythmia in the world and its prevalence increases with age. The main and most severe complication of AF is ischemic stroke. Oral anticoagulation (OAC) therapy is the standard of care for stroke prevention in the high risk population. Initiation of this treatment is associated with a substantial risk of bleeding complications. Moreover, there is a group of patients who cannot tolerate OAC. In patients with AF the left atrial appendage (LAA) is the main source of thrombus formation. Percutaneous left atrial appendage closure (LAAC) has become an important non-pharmacological intervention for stroke prevention in patients with non-valvular AF. The procedure aims to reduce the risk of thromboembolism without increasing the risk of bleeding. Over the last few years, the safety and long-term efficacy of the procedure in specific populations have increased and more patients are being treated. The Watchman device is the most studied device in this field. Randomized controlled trials demonstrated non-inferiority of percutaneous left atrial appendage closure using the WATCHMAN 2.5 device to OAC (Boston Scientific, Marlborough, MA, USA). The new generation device, WATCHMAN FLX, was introduced and its use was associated with fewer safety events and a higher success rate of effective appendage closure. Nevertheless, several unsolved problems remain, including device-related thrombosis, the post-LAAC antithrombotic regimen, and peri-device leakage. This review will focus on LAAC with the Watchman device for stroke prevention in AF patients. Current status, available literature, clinical safety and efficacy will be summarized.

Indexed as

atrial fibrillationdevice-related thrombusleft atrial appendage closureperi-device leak

Identifiers

PMID38616940
PMCPMC11008520
OpenAlexW4393074806

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.