Evidence map›Paper›PMID 38615078›Full record

ArticleAnnals of biomedical engineering2024

In Vitro Comparison of a Closed and Semi-closed Leaflet Design for Adult and Pediatric Transcatheter Heart Valves.

Alexander Breitenstein-Attach, Marvin Steitz, Xiaolin Sun, Yimeng Hao, Jonathan Kiekenap, Jasper Emeis, Sugat Ratna Tuladhar, Felix Berger, Boris Schmitt

Open access · hybridAbstract readComparative Study
In one paragraph

Article in Annals of biomedical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Alexander Breitenstein-AttachDepartment of Pediatric Cardiology and Congenital Heart Disease, German Heart Center Berlin (Charité), Augustenburger Platz 1, Berlin, Germany. alexander.breitenstein@dhzc-charite.de.ORCID http://orcid.org/0000-0001-7006-2897
Marvin SteitzDepartment of Pediatric Cardiology and Congenital Heart Disease, German Heart Center Berlin (Charité), Augustenburger Platz 1, Berlin, Germany.
Xiaolin SunDepartment of Pediatric Cardiology and Congenital Heart Disease, German Heart Center Berlin (Charité), Augustenburger Platz 1, Berlin, Germany.
Yimeng HaoDepartment of Pediatric Cardiology and Congenital Heart Disease, German Heart Center Berlin (Charité), Augustenburger Platz 1, Berlin, Germany.
Jonathan KiekenapDepartment of Pediatric Cardiology and Congenital Heart Disease, German Heart Center Berlin (Charité), Augustenburger Platz 1, Berlin, Germany.
Jasper EmeisDepartment of Pediatric Cardiology and Congenital Heart Disease, German Heart Center Berlin (Charité), Augustenburger Platz 1, Berlin, Germany.
Sugat Ratna TuladharDepartment for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Carl-Neuberg-Straße 1, Hannover, Germany.
Felix BergerDepartment of Pediatric Cardiology and Congenital Heart Disease, German Heart Center Berlin (Charité), Augustenburger Platz 1, Berlin, Germany.
Boris SchmittDepartment of Pediatric Cardiology and Congenital Heart Disease, German Heart Center Berlin (Charité), Augustenburger Platz 1, Berlin, Germany.
Deutsches Herzzentrum der Charité · DEMedizinische Hochschule Hannover · DE

Funding

Bundesministerium für Bildung und Forschung 13GW0498A Kinderherzklappe
6 · The paper itself

Abstract

Transcatheter heart valve replacements (TVR) are mostly designed in a closed position (c) with leaflets coaptating. However, recent literature suggests fabricating valves in semi-closed (sc) position to minimize pinwheeling. With about 100,000 children in need of a new pulmonary valve each year worldwide, this study evaluates both geometrical approaches in adult as well as pediatric size and condition. Three valves of each geometry were fabricated in adult (30 mm) and pediatric (15 mm) size, using porcine pericardium. To evaluate performance, the mean transvalvular pressure gradient (TPG), effective orifice area (EOA), and regurgitation fraction (RF) were determined in three different annulus geometries (circular, elliptic, and tilted). For both adult-sized valve geometries, the TPG (TPG

Indexed as

Heart Valve ProsthesisProsthesis DesignAdultAnimalsChildHumansModels, CardiovascularSwineCongenital heart diseasePinwheelingPulmonary valveTranscatheter heart valve replacementValve geometry

Identifiers

PMID38615078
PMCPMC11247063
OpenAlexW4394781281

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.