Evidence map›Paper›PMID 38610923›Full record

ArticleCancers2024

Enhancing Image-Guided Radiation Therapy for Pancreatic Cancer: Utilizing Aligned Peak Response Beamforming in Flexible Array Transducers.

Ziwei Feng, Edward Sun, Debarghya China, Xinyue Huang, Hamed Hooshangnejad, Eduardo A Gonzalez, Muyinatu A Lediju Bell, Kai Ding

Open access · goldAbstract read
In one paragraph

Article in Cancers, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Ziwei FengDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA.
Edward SunDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA.ORCID 0009-0000-7788-3567
Debarghya ChinaDepartment of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA.
Xinyue HuangDepartment of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA.ORCID 0000-0001-5202-3368
Hamed HooshangnejadDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA.ORCID 0000-0002-1953-0568
Eduardo A GonzalezDepartment of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
Muyinatu A Lediju BellDepartment of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.ORCID 0000-0002-8394-4482
Kai DingDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA.ORCID 0000-0002-8202-0173
Johns Hopkins University · US

Funding

Spacer Enabled Robust Radiation Therapy (SERRT)R37CA229417 · NCI · JOHNS HOPKINS UNIVERSITY · PI DING, KAI · 2018 to 2021
$1.5M
NCI NIH HHS R37 CA229417NIH HHS R37CA229417
6 · The paper itself

Abstract

To develop ultrasound-guided radiotherapy, we proposed an assistant structure with embedded markers along with a novel alternative method, the Aligned Peak Response (APR) method, to alter the conventional delay-and-sum (DAS) beamformer for reconstructing ultrasound images obtained from a flexible array. We simulated imaging targets in Field-II using point target phantoms with point targets at different locations. In the experimental phantom ultrasound images, image RF data were acquired with a flexible transducer with in-house assistant structures embedded with needle targets for testing the accuracy of the APR method. The lateral full width at half maximum (FWHM) values of the objective point target (OPT) in ground truth ultrasound images, APR-delayed ultrasound images with a flat shape, and images acquired with curved transducer radii of 500 mm and 700 mm were 3.96 mm, 4.95 mm, 4.96 mm, and 4.95 mm. The corresponding axial FWHM values were 1.52 mm, 4.08 mm, 5.84 mm, and 5.92 mm, respectively. These results demonstrate that the proposed assistant structure and the APR method have the potential to construct accurate delay curves without external shape sensing, thereby enabling a flexible ultrasound array for tracking pancreatic tumor targets in real time for radiotherapy.

Indexed as

image guidance radiotherapyultrasound beamformingultrasound image

Identifiers

PMID38610923
PMCPMC11011135
OpenAlexW4393068845

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.