Evidence map›Paper›PMID 38610443›Full record

ArticleSensors (Basel, Switzerland)2024

Innovative Metaheuristic Optimization Approach with a Bi-Triad for Rehabilitation Exoskeletons.

Deira Sosa Méndez, Cecilia E García Cena, David Bedolla-Martínez, Antonio Martín González

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Deira Sosa MéndezEscuela Técnica Superior de Ingeniería y Diseño Industrial, Center for Automation and Robotics, UPM-CSIC, Universidad Politécnica de Madrid, Ronda de Valencia, 3, 28012 Madrid, Spain.ORCID 0000-0002-3290-2039
Cecilia E García CenaEscuela Técnica Superior de Ingeniería y Diseño Industrial, Center for Automation and Robotics, UPM-CSIC, Universidad Politécnica de Madrid, Ronda de Valencia, 3, 28012 Madrid, Spain.ORCID 0000-0002-1067-0564
David Bedolla-MartínezElectrical Engineering, École de Technologie Supérieure, 1100 Notre-Dame St. W, Montreal, QC H3C 1K3, Canada.ORCID 0000-0001-8552-6842
Antonio Martín GonzálezUnidad de Tecnologías Avanzadas en Diseño e Impresión 3D, Hospital Universitario 12 de Octubre, Av. de Córdoba, s/n, 28041 Madrid, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The present work proposes a comprehensive metaheuristic methodology for the development of a medical robot for the upper limb rehabilitation, which includes the topological optimization of the device, kinematic models (5 DOF), human-robot interface, control and experimental tests. This methodology applies two cutting-edge triads: (1) the three points of view in engineering design (client, designer and community) and (2) the triad formed by three pillars of Industry 4.0 (autonomous machines and systems, additive manufacturing and simulation of virtual environments). By applying the proposed procedure, a robotic mechanism was obtained with a reduction of more than 40% of its initial weight and a human-robot interface with three modes of operation and a biomechanically viable kinematic model for humans. The digital twin instance and its evaluation through therapeutic routines with and without disturbances was assessed; the average RMSEs obtained were 0.08 rad and 0.11 rad, respectively. The proposed methodology is applicable to any medical robot, providing a versatile and effective solution for optimizing the design and development of healthcare devices. It adopts an innovative and scalable approach to enhance their processes.

Indexed as

Exoskeleton DeviceRoboticsCommerceComputer SimulationEngineeringHumansIndustry 4.0rehabilitation roboticstopological optimizationupper limb exoskeleton

Identifiers

PMID38610443
PMCPMC11014224

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.