Evidence map›Paper›PMID 38610390›Full record

ArticleSensors (Basel, Switzerland)2024

Piezoceramics Actuator with Attached Mass for Active Vibration Diagnostics of Reinforced Concrete Structures.

Igor Shardakov, Aleksey Shestakov, Irina Glot, Georgii Gusev, Valery Epin, Roman Tsvetkov

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Igor ShardakovInstitute of Continuous Media Mechanics, Ural Branch of Russian Academy of Science, Academician Korolev Street 1, 614013 Perm, Russia.
Aleksey ShestakovInstitute of Continuous Media Mechanics, Ural Branch of Russian Academy of Science, Academician Korolev Street 1, 614013 Perm, Russia.ORCID 0000-0003-3387-7442
Irina GlotInstitute of Continuous Media Mechanics, Ural Branch of Russian Academy of Science, Academician Korolev Street 1, 614013 Perm, Russia.ORCID 0000-0002-2842-7511
Georgii GusevInstitute of Continuous Media Mechanics, Ural Branch of Russian Academy of Science, Academician Korolev Street 1, 614013 Perm, Russia.
Valery EpinInstitute of Continuous Media Mechanics, Ural Branch of Russian Academy of Science, Academician Korolev Street 1, 614013 Perm, Russia.
Roman TsvetkovInstitute of Continuous Media Mechanics, Ural Branch of Russian Academy of Science, Academician Korolev Street 1, 614013 Perm, Russia.ORCID 0000-0001-9617-407X

Funding

Russian Science Foundation 22-19-00108
6 · The paper itself

Abstract

One of the effective methods of non-destructive testing of structures is active vibration diagnostics. This approach consists of the local dynamic impact of the actuator on the structure and the registration of the vibration response. Testing of massive reinforced concrete structures is carried out with the use of actuators, which are able to create sufficiently high-impact loads. The actuators, which are based on piezoelectric elements, cannot provide a sufficient level of force and the areas where it is possible to register the vibrations excited by such actuators are quite small. In this paper, we propose a variant of a piezoactuator with attached mass, which ensures an increase in the level of dynamic impact on the structure. The effectiveness of this version is verified by numerical modeling of the dynamic interaction of the actuator with a concrete slab. The simulation was carried out within the framework of the theory of elasticity and coupled electroelasticity. An algorithm for selecting the value of the attached mass is described. It is shown that when vibrations are excited in a massive concrete slab, an actuator with an attached mass of 1.3 kg provides a 10,000-fold increase in the force compared to an actuator without attached mass. In the pulse mode, a 100-fold increase in force is achieved.

Indexed as

attached masselectroelasticitynon-destructive testingnumerical simulationpiezoceramic actuatorvibration diagnostics

Identifiers

PMID38610390
PMCPMC11014227

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked