ArticleSensors (Basel, Switzerland)2024
Heart Rate Variability and Pulse Rate Variability: Do Anatomical Location and Sampling Rate Matter?
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07616674 (Correlation Between the R-R Interval of the Electrocardiogram and the Intracranial Pulse Wave Interval Assessed by a Noninvasive Method in Healthy People), which is not on this map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Correlation Between the R-R Interval of the Electrocardiogram and the Intracranial Pulse Wave Interval Assessed by a Noninvasive Method in Healthy People
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.
- Accuracy of Photoplethysmography-Derived Pulse Rate Variability Compared with Electrocardiography-Derived Heart Rate Variability: A Systematic Review and Meta-Analysis.Sensors (Basel, Switzerland) · 2026Pooled it
- Consumer Smartwatch Technology in Health and Performance Research: Validity, Limitations, and Real-World Applications.Sensors (Basel, Switzerland) · 2026Review
- Pulse Rate Variability Is Not the Same as Heart Rate Variability: Implications for Sports Performance and Injury Prevention.Sports medicine - open · 2026Article
- Advancing remote photoplethysmography (rPPG) to facilitate cardiac monitoring in naturalistic settings using webcam technology.Behavior research methods · 2026Article
- Validation of a Wearable Photoplethysmography-Based Sensor for Compensatory Reserve Measurement Monitoring in Simulated Human Hemorrhage.Sensors (Basel, Switzerland) · 2026Article
- Smart Steering Wheel Prototype for In-Vehicle Vital Sign Monitoring.Sensors (Basel, Switzerland) · 2026Article
- Brain-heart coupling in tourette syndrome: a precision functional mapping study of discordant siblings.Frontiers in network physiology · 2026Article
- Are Wearable ECG Devices Ready for Hospital at Home Application?Sensors (Basel, Switzerland) · 2025Review
- Validity of Ultra-Short-Term Heart Rate Variability Derived from Femoral Arterial Pulse Waveform in a British Military Cohort.Applied psychophysiology and biofeedback · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
Wearable technology and neuroimaging equipment using photoplethysmography (PPG) have become increasingly popularized in recent years. Several investigations deriving pulse rate variability (PRV) from PPG have demonstrated that a slight bias exists compared to concurrent heart rate variability (HRV) estimates. PPG devices commonly sample at ~20-100 Hz, where the minimum sampling frequency to derive valid PRV metrics is unknown. Further, due to different autonomic innervation, it is unknown if PRV metrics are harmonious between the cerebral and peripheral vasculature. Cardiac activity via electrocardiography (ECG) and PPG were obtained concurrently in 54 participants (29 females) in an upright orthostatic position. PPG data were collected at three anatomical locations: left third phalanx, middle cerebral artery, and posterior cerebral artery using a Finapres NOVA device and transcranial Doppler ultrasound. Data were sampled for five minutes at 1000 Hz and downsampled to frequencies ranging from 20 to 500 Hz. HRV (via ECG) and PRV (via PPG) were quantified and compared at 1000 Hz using Bland-Altman plots and coefficient of variation (CoV). A sampling frequency of ~100-200 Hz was required to produce PRV metrics with a bias of less than 2%, while a sampling rate of ~40-50 Hz elicited a bias smaller than 20%. At 1000 Hz, time- and frequency-domain PRV measures were slightly elevated compared to those derived from HRV (mean bias: ~1-8%). In conjunction with previous reports, PRV and HRV were not surrogate biomarkers due to the different nature of the collected waveforms. Nevertheless, PRV estimates displayed greater validity at a lower sampling rate compared to HRV estimates.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.