Evidence map›Paper›PMID 38610255›Full record

ArticleSensors (Basel, Switzerland)2024

Reliability Evaluation for Continuous-Wave Functional Near-Infrared Spectroscopy Systems: Comprehensive Testing from Bench Characterization to Human Test.

Chenyang Gao, Jia Xiu, Chong Huang, Kaixue Ma, Ting Li

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Chenyang GaoInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China.
Jia XiuInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China.
Chong HuangPhilips North America, Carlsbad, CA 92011, USA.
Kaixue MaSchool of Microelectronics, Tianjin University, Tianjin 300072, China.
Ting LiInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China.ORCID 0000-0001-5145-3024
Chinese Academy of Medical Sciences & Peking Union Medical College · CNPhilips (United States) · USTianjin University · CN

Funding

CAMS Innovation Fund for Medical Sciences 2022-I2M-c&T-B-012 and 2022-I2M-C&T-B-095Chinese Academy of Medical Science health innovation project 2021-I2M-042, 2021-I2M-058, and 2022-I2M-C&T-A-005National Natural Science Foundation of China 81971660, 82305438Sichuan Science and Technology Program 2021YFH0004Tianjin Outstanding Youth Fund Project 20JCJQIC00230
6 · The paper itself

Abstract

In recent years, biomedical optics technology has developed rapidly. The current widespread use of biomedical optics was made possible by the invention of optical instruments. The advantages of being non-invasive, portable, effective, low cost, and less susceptible to system noise have led to the rapid development of functional near-infrared spectroscopy (fNIRS) technology for hemodynamics detection, especially in the field of functional brain imaging. At the same time, laboratories and companies have developed various fNIRS-based systems. The safety, stability, and efficacy of fNIRS systems are key performance indicators. However, there is still a lack of comprehensive and systematic evaluation methods for fNIRS instruments. This study uses the fNIRS system developed in our laboratory as the test object. The test method established in this study includes system validation and performance testing to comprehensively assess fNIRS systems' reliability. These methods feature low cost and high practicality. Based on this study, existing or newly developed systems can be comprehensively and easily evaluated in the laboratory or workspace.

Indexed as

Biomedical TechnologySpectroscopy, Near-InfraredBrainHumansLaboratoriesReproducibility of Resultsfunctional near-infrared spectroscopyoptical detectionoptical instrumentreliability evaluation

Identifiers

PMID38610255
PMCPMC11014010
OpenAlexW4393158650

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.