Evidence map›Paper›PMID 38610244›Full record

ArticleSensors (Basel, Switzerland)2024

Topology Optimization Design Method for Acoustic Imaging Array of Power Equipment.

Jun Xiong, Xiaoming Zha, Xuekai Pei, Wenjun Zhou

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jun XiongSchool of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China.
Xiaoming ZhaSchool of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China.
Xuekai PeiSchool of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China.
Wenjun ZhouSchool of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Acoustic imaging technology has the advantages of non-contact and intuitive positioning. It is suitable for the rapid positioning of defects such as the mechanical loosening, discharge, and DC bias of power equipment. However, the existing research lacks the optimization design of microphone array topology. The acoustic frequency domain characteristics of typical power equipment are elaborately sorted out. After that, the cut-off frequencies of acoustic imaging instruments are determined, to meet the needs of the full bandwidth test requirements. Through a simulation calculation, the circular array is demonstrated to be the optimal shape. And the design parameters affect the imaging performance of the array to varying degrees, indicating that it is difficult to obtain the optimal array topology by an exhaustive method. Aimed at the complex working conditions of power equipment, a topology optimization design method of an acoustic imaging array for power equipment is proposed, and the global optimal solution of microphone array topology is obtained. Compared with the original array, the imaging performance of the improved LF and HF array is promoted by 54% and 49%, respectively. Combined with the simulation analysis and laboratory test, it is verified that the improved array can not only accurately locate the single sound source but also accurately identify the main sound source from the interference of the contiguous sound source.