Changes in temperature in preheated crystalloids at ambient temperatures relevant to a prehospital setting: an experimental simulation study with the application of prehospital treatment of trauma patients suffering from accidental hypothermia.
Article in BMC emergency medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 0 citations in OpenAlex.
- Accidental hypothermia.Nature reviews. Disease primers · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAccidental hypothermia is common in all trauma patients and contributes to the lethal diamond, increasing both morbidity and mortality. In hypotensive shock, fluid resuscitation is recommended using fluids with a temperature of 37-42°, as fluid temperature can decrease the patient's body temperature. In Sweden, virtually all prehospital services use preheated fluids. The aim of the present study was to investigate how the temperature of preheated infusion fluids is affected by the ambient temperatures and flow rates relevant for prehospital emergency care.
methodsIn this experimental simulation study, temperature changes in crystalloids preheated to 39 °C were evaluated. The fluid temperature changes were measured both in the infusion bag and at the patient end of the infusion system. Measurements were conducted in conditions relevant to prehospital emergency care, with ambient temperatures varying between - 4 and 28 °C and flow rates of 1000 ml/h and 6000 ml/h, through an uninsulated infusion set at a length of 175 cm.
resultsThe flow rate and ambient temperature affected the temperature in the infusion fluid both in the infusion bag and at the patient end of the system. A lower ambient temperature and lower flow rate were both associated with a greater temperature loss in the infusion fluid.
conclusionThis study shows that both a high infusion rate and a high ambient temperature are needed if an infusion fluid preheated to 39 °C is to remain above 37 °C when it reaches the patient using a 175-cm-long uninsulated infusion set. It is apparent that the lower the ambient temperature, the higher the flow rate needs to be to limit temperature loss of the fluid.
Indexed as