Evidence map›Paper›PMID 38606325›Full record

ArticleJournal of hip preservation surgery2024

Development of a simulation system for femoroacetabular impingement detection based on 3D images.

Chun-Ming Chen, Shang-Chih Lin, Chen-Te Wu, Yi-Sheng Chan

Open access · diamondAbstract read
In one paragraph

Article in Journal of hip preservation surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 66% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. The Management of Acetabular Labral Tears: A Contemporary Review.Current reviews in musculoskeletal medicine · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Chun-Ming ChenTaiwan High Speed 3D Printing Research Center, National Taiwan University of Science and Technology, No. 43, Sec. 4, Keelung Rd., Da'an Dist., Taipei, Taiwan.ORCID https://orcid.org/0000-0002-9142-1542
Shang-Chih LinTaiwan High Speed 3D Printing Research Center, National Taiwan University of Science and Technology, No. 43, Sec. 4, Keelung Rd., Da'an Dist., Taipei, Taiwan.
Chen-Te WuDepartment of Medical Imaging and Intervention, Chang Gung Memorial Hospital, No. 5, Fuxing St., Guishan Dist., Taoyuan, Taiwan.
Yi-Sheng ChanDepartment of Orthopedic Surgery, Chang Gung Memorial Hospital, No. 222, Maijin Rd., Anle Dist., Keelung, Taiwan.ORCID https://orcid.org/0000-0001-7413-1431
Chang Gung Memorial Hospital · TWNational Taiwan University of Science and Technology · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Image-based criteria have been adopted to diagnose femoroacetabular impingement (FAI). However, the overlapping property of the two-dimensional X-ray outlines and static and supine posture of taking computed tomography (CT) and magnetic resonance imaging images potentially affect the accuracy of the criteria. This study developed a CT image-based dynamic criterion to effectively simulate FAI, thereby providing a basis for physicians to perform pre-operative planning for arthroscopic surgery. Post-operative CT images of 20 patients with satisfactory surgical results were collected, and 10 sets of models were used to define the flexion rotation centre (FRC) of the three-dimensional FAI model. First, let these 10 groups of models simulate the FAI detection action and find the best centre offset, and then FRC is the result of averaging these 10 groups of best displacements. The model was validated in 10 additional patients. Finally, through the adjustment basis of FRC, the remaining 10 sets of models can find out the potential position of FAI during the dynamic simulation process. Rotational collisions detected using FRC indicate that the patient's post-operative flexion angle may reach 120° or greater, which is close to the actual result. The recommended surgical range of the diagnostic system (average length of 6.4 mm, width of 4.1 mm and depth of 3.2 mm) is smaller than the actual surgical results, which prevents the doctor from performing excessive resection operations, which may preserve more bones. The FRC diagnostic system detects the distribution of FAI in a simple manner. It can be used as a pre-operative diagnosis reference for clinicians, hoping to improve the effect and accuracy of debridement surgery.

Identifiers

PMID38606325
PMCPMC11005768
OpenAlexW4388609888

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.