ArticleComputers in biology and medicine2024
A mathematical model of tissue axial and radial diffusion in the microvasculature for intravascular microscopy and phosphorescence quenching data.
Article in Computers in biology and medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
This study aims to extend earlier Krogh Cylinder Models of an oxygen profile by considering axial diffusion and analytically solving Fick's Law Partial Differential Equation with novel boundary conditions via the separation of variables. We next prospectively collected a total of 20 animals, which were randomly assigned to receive either fresh or two-week-old stored red blood cell (RBC) transfusions and PQM oxygen data were measured acutely (90 min) or chronically (24 h). Transfusion effects were evaluated in vivo using intravital microscopy of the dorsal skinfold window chamber in Golden Syrian Hamsters. Hamsters were initially hemorrhaged by 50% of total blood volume and resuscitated 1-h post hemorrhage. PQM data were subsequently collected and fit the derived 2D Krogh cylinder model. Systemic hemodynamics (mean arterial pressure, heart rate) were similar in both pre and post-transfusion with either stored or fresh cells. Transfusion with stored cells was found to impair axial and radial oxygen gradients as quantified by our model and consistent with previous studies. Specifically, we observed a statistically significant decrease in the arteriolar tissue radial oxygen gradient after transfusion with stored RBCs at 24 h compared with fresh RBCs (0.33 ± 0.17 mmHg μ m-1 vs, 0.14 ± 0.12 mmHg μ m-1; p = 0.0280). We also observed a deficit in the arteriolar tissue oxygen gradient (0.03 ± 0.01 mmHg μ m-1 fresh vs. 0.018 ± 0.007 mmHg μ m-1 stored; p = 0.0185). We successfully derived and validated an analytical 2D Krogh cylinder model in an animal model of microhemodynamic oxygen diffusion aberration secondary to storage lesions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.