Evidence map›Paper›PMID 38601441›Full record

ReviewTranslational lung cancer research2024

The use of intravenous indocyanine green in minimally invasive segmental lung resections: a systematic review.

Maxim Peeters, Yanina Jansen, Jean H T Daemen, Lori M van Roozendaal, Paul De Leyn, Karel W E Hulsewé, Yvonne L J Vissers, Erik R de Loos

Abstract readReview
In one paragraph

Review in Translational lung cancer research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Maxim PeetersDepartment of Thoracic Surgery, University Hospitals Leuven, Leuven, Belgium.ORCID https://orcid.org/0000-0001-8220-9921
Yanina JansenDepartment of Thoracic Surgery, University Hospitals Leuven, Leuven, Belgium.
Jean H T DaemenDivision of Thoracic Surgery, Department of General Surgery, Zuyderland Medical Center, Heerlen, The Netherlands.
Lori M van RoozendaalDepartment of Thoracic Surgery, University Hospitals Leuven, Leuven, Belgium.
Paul De LeynDepartment of Thoracic Surgery, University Hospitals Leuven, Leuven, Belgium.
Karel W E HulsewéDivision of Thoracic Surgery, Department of General Surgery, Zuyderland Medical Center, Heerlen, The Netherlands.
Yvonne L J VissersDivision of Thoracic Surgery, Department of General Surgery, Zuyderland Medical Center, Heerlen, The Netherlands.
Erik R de LoosDivision of Thoracic Surgery, Department of General Surgery, Zuyderland Medical Center, Heerlen, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: To identify intersegmental planes (ISPs) in video/robot-assisted thoracoscopic segmentectomies, indocyanine green (ICG) is commonly used. The aim of this systematic review is to evaluate the efficacy of intravenous ICG in the identification of ISP. Methods: A systematic search was performed. Studies evaluating patients who underwent a video/robot-assisted thoracoscopic segmentectomy using intravenous ICG were included. The primary outcome measure was the frequency and percentage of patients in whom the ISP was adequately visualized. Secondary outcomes encompassed the ICG dose, time to visualization, time to maximum ICG visualization, time to disappearance of ICG effect and adverse reactions to ICG. Results: Eighteen studies were included for systematic review, enrolling a total of 1,090 patients. Irrespective of the injected dose, intravenous ICG identified the ISP in 94% of the cases (range, 30-100%). Overall, there was a considerable amount of heterogeneity regarding the injected dose of ICG (range, 5-25 mg or 0.05-0.5 mg/kg). The mean time before first effect of ICG was visible ranged from 10 to 40 seconds. The mean total time of ICG visibility ranged from 90 to 140 seconds after a bolus injection and was 170 seconds after continuous infusion. No adverse reactions were reported. Conclusions: After administration of intravenous ICG, visualization of the ISP is successful in up to 94% of cases, even after administration of a low dose (0.05 mg/kg) of ICG. The use of intravenous ICG is safe with no reported adverse effects in the immediate peri-operative period.

Indexed as

indocyanine green (ICG)lung segmentectomyNear-infrared (NIR)

Identifiers

PMID38601441
PMCPMC11002498

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked