Evidence map›Paper›PMID 38601295›Full record

ArticleGland surgery2024

Normative electromyography data and influencing factors in intraoperative neuromonitoring using adhesive skin electrodes during thyroid surgery.

Sung-Chan Shin, Yong-Il Cheon, Minhyung Lee, Eui-Suk Sung, Jin-Choon Lee, Mijin Kim, Bo Hyun Kim, Byung-Joo Lee

Open access · diamondAbstract read
In one paragraph

Article in Gland surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
4.0field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Comparison of EMG responses obtained from endotracheal tube and thyroid cartilage surface electrodes in thyroidectomies performed with intraoperative nerve monitoring.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Sung-Chan ShinDepartment of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea.ORCID https://orcid.org/0000-0003-2329-0648
Yong-Il CheonDepartment of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea.ORCID https://orcid.org/0000-0003-0288-0542
Minhyung LeeDepartment of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea.ORCID https://orcid.org/0000-0002-4038-1667
Eui-Suk SungDepartment of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea.ORCID https://orcid.org/0000-0001-8752-3426
Jin-Choon LeeDepartment of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea.ORCID https://orcid.org/0000-0002-5629-4277
Mijin KimBiomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea.ORCID https://orcid.org/0000-0002-1538-8859
Bo Hyun KimBiomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea.ORCID https://orcid.org/0000-0001-9632-9457
Byung-Joo LeeDepartment of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea.ORCID https://orcid.org/0000-0001-7091-6688
Pusan National University Hospital · KRPusan National University Yangsan Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Skin electrodes have been reported to be a useful alternative recording method for intraoperative neuromonitoring (IONM) and show typical electromyography (EMG) waveforms while overcoming the shortcomings of the EMG endotracheal tube. However, the skin electrodes showed relatively lower evoked amplitudes than other recording methods. In this study, we analyzed normative EMG data using skin electrodes and factors that affect the evoked amplitude of thyroid IONM. Methods: In total, 167 patients [242 nerves at risk (NAR)] who underwent thyroidectomy under IONM with adhesive skin electrodes were analyzed. A pair of skin electrodes was attached to the lateral border of the lamina of the thyroid cartilage. Evoked EMG data, including mean amplitude and latency, obtained after stimulation of the recurrent laryngeal nerve (RLN) and vagus nerve (VN), were collected and analyzed. Results: The mean amplitudes of RLN and VN recorded via skin electrodes were 255.48±96.53 and 236.15±69.72 μV, respectively. The mean latency of the right and left RLN was 3.22±0.03 and 3.49±0.08 mS, respectively. The mean latency of the right and left VN was 5.37±0.80 and 7.57±0.10 mS, respectively. The mean amplitude was significantly lower in the obesity, male, and total thyroidectomy (TT) groups. As body mass index (BMI) and age increased, the amplitude of EMG tended to decrease significantly. Conclusions: The evoked amplitude recorded with the skin electrodes was relatively low. A larger surgical extent, obesity, male sex, and age >55 years showed significantly lower evoked amplitudes.

Indexed as

electrodesNeuromuscular monitoringrecurrent laryngeal nerve (RLN)thyroid glandvagus nerve (VN)

Identifiers

PMID38601295
PMCPMC11002475
OpenAlexW4393050613

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.