Trial reportThe western journal of emergency medicine2024
Diagnostic Accuracy of a Handheld Ultrasound vs a Cart-based Model: A Randomized Clinical Trial.
Trial report in The western journal of emergency medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05196776 (Diagnostic Accuracy of a Portable, Handheld Point-of-Care Ultrasound Device vs a Traditional Cart-Based Model), which is not on this map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Diagnostic Accuracy of a Portable, Handheld Point-of-Care Ultrasound Device vs a Traditional Cart-Based Model
Who cites it
13 citing papers in PubMed.
- Wireless versus cart-based ultrasound in musculoskeletal and superficial soft-tissue imaging: a prospective blinded cross-over study.Journal of ultrasound · 2026Article
- Diagnostic accuracy and clinical impact of internist-performed point-of-care ultrasound in atrial fibrillation: a multicenter study.Internal and emergency medicine · 2026Article
- Handheld point-of-care ultrasound for chairside assessment of masseter muscle: a pilot study.Oral radiology · 2026Article
- Advances and Challenges of Capacitive Micromachined Ultrasonic Transducers in Medical Imaging.Micromachines · 2026Review
- Validation of Family Medicine Point-of-Care Ultrasound Screening (POCUS) for Abdominal Aortic Aneurysm.Journal of the American Board of Family Medicine : JABFM · 2026Observational
- The Assessment of the Tendon of Insertion of the Iliopsoas Muscle in Dogs Using Diagnostic Ultrasound Has Good Intraobserver Consistency but Lacks Interobserver Consistency.Animals : an open access journal from MDPI · 2026Article
- Cardiovascular response to altered gravity in healthy adults: Insight from graded tilt testing.Physiological reports · 2026Article
- Optimizing transducer choice for the detection of alveolar-interstitial syndrome in dogs and cats: an evidence-based review.Frontiers in veterinary science · 2026Review
- Point-of-Care Ultrasound in Undergraduate Medical Education: A National Survey.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025Article
- A comparative study of portable ultrasound devices in the evaluation of Atlantic bottlenose dolphin mammary gland morphology.Biology letters · 2025Article
- POC Sensor Systems and Artificial Intelligence-Where We Are Now and Where We Are Going?Biosensors · 2025Review
- Reliability of spectral Doppler in handheld ultrasonographic device.The international journal of cardiovascular imaging · 2025Article
- Standard to Handheld: A New Wave in Thoracic Ultrasound and Patient Care-A Direct Comparison of Portable Handheld Against Standard in Thoracic Ultrasound.Medicina (Kaunas, Lithuania) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Numerous studies have demonstrated the accuracy of point-of-care ultrasound (POCUS). Portable, handheld devices have expanded the clinical scope of POCUS at a fraction of the cost of traditional, cart-based models. There is a paucity of data assessing the diagnostic accuracy of portable devices. Our objective in this study was to compare the diagnostic accuracy of a portable device with a cart-based model. Methods: This was an institutional review board-approved, observational, prospective, randomized clinical trial (NCT05196776) of a convenience sample of adult patients who presented to a university-based health system. Patients who required a cardiac, lung, renal, aorta, or biliary POCUS were randomized to a portable device or to a cart-based model. We hypothesized that the cart-based model would have a 90% diagnostic accuracy vs 70% for the handheld device. To detect a 20% difference, the sample size was calculated to be 98, with 49 patients randomized to each arm. We used standard 2x2 tables to calculate test characteristics with 95% confidence intervals (CI). Results: A total of 110 patients were enrolled, with 56 patients randomized to the cart-based model and 54 to the handheld device. The sensitivity, specificity, and diagnostic accuracy of the cart-based vs handheld were 77.8% (40-97.2) vs 92.9% (66.1-99.8), 91.5% (79.6-97.6) vs 92.3% (79.1-98.4%), and 89.3% (78.1-96) vs 92.5% (81.8-97.9), respectively. Conclusion: The diagnostic accuracy of a portable, handheld device is similar to that of a cart-based model.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.