Evidence map›Paper›PMID 38594483›Full record

ReviewJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2024

Management of aortic valve insufficiency in patients with continuous-flow left ventricular assist device: a republication of the review published in Japanese Journal of Artificial Organs.

Naoki Tadokoro, Kohei Tonai, Satoshi Kainuma, Naonori Kawamoto, Kota Suzuki, Masaya Hirayama, Satsuki Fukushima

Abstract readReview
PubMed Publisher
In one paragraph

Review in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 57% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Naoki TadokoroDepartment of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, 6-7 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan. n.tadokoro@ncvc.go.jp.
Kohei TonaiDepartment of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, 6-7 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan.
Satoshi KainumaDepartment of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, 6-7 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan.
Naonori KawamotoDepartment of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, 6-7 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan.
Kota SuzukiDepartment of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, 6-7 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan.
Masaya HirayamaDepartment of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, 6-7 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan.
Satsuki FukushimaDepartment of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, 6-7 Kishibeshinmachi, Suita, Osaka, 564-8565, Japan. s.fukushima@ncvc.go.jp.
National Cerebral and Cardiovascular Center · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Since 2011, implantable ventricular assist devices have been a standard treatment for severe heart failure alongside heart transplantation in Japan. However, the limited availability of donors has led to a prolonged wait for transplants, now averaging 1719 days, intensifying the issue of aortic insufficiency in patients with continuous flow ventricular assist devices. These devices limit the opening of the aortic valve, leading to sustained closure and increased shear stress, which accelerates valve degradation. Risk factors for aortic insufficiency include having a smaller body surface area, being of advanced age, and the presence of mild aortic insufficiency prior to device implantation. In patients presenting with mild or moderate aortic regurgitation at the time of ventricular assist device implantation, interventions such as aortic valve repair or bioprosthetic valve replacement are performed with the aim of halting its progression. The choice of surgical procedure should be tailored to each patient's individual condition. The management of de novo aortic insufficiency in patients with continuous flow ventricular assist devices remains challenging, with no clear consensus on when to intervene. Interventions for significant aortic insufficiency typically consider the patient's symptoms and aortic insufficiency severity. De novo aortic insufficiency progression in continuous flow ventricular assist devices patients necessitates careful monitoring and intervention based on individual patient assessments and valve condition. This review was created based on a translation of the Japanese review written in the Japanese Journal of Artificial Organs in 2023 (Vol. 52, No. 1, pp. 77-80), with some modifications.

Indexed as

Aortic Valve InsufficiencyHeart-Assist DevicesHeart FailureHumansJapanAortic insufficiencyHeart failureVentricular assist device

Identifiers

PMID38594483
OpenAlexW4394692858

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.