Evidence map›Paper›PMID 38594267›Full record

ArticleScientific reports2024

Augmenting authenticity for non-invasive in vivo detection of random blood glucose with photoacoustic spectroscopy using Kernel-based ridge regression.

P N S B S V Prasad V, Ali Hussain Syed, Mudigonda Himansh, Biswabandhu Jana, Pranab Mandal, Pradyut Kumar Sanki

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
9.3field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

P N S B S V Prasad VDepartment of Electronics and Communication Engineering, SRM University -AP, Neerukonda, 522240, India.
Ali Hussain SyedDepartment of Electronics and Communication Engineering, SRM University -AP, Neerukonda, 522240, India.
Mudigonda HimanshDepartment of Computer Science and Engineering, SRM University -AP, Neerukonda, 522240, India.
Biswabandhu JanaDepartment of Electrical and Electronics Engineering, ABV-IIITM Gwalior, Gwalior, MP, 474015, India.
Pranab MandalDepartment of Physics, SRM University -AP, Neerukonda, 522240, India.
Pradyut Kumar SankiDepartment of Electronics and Communication Engineering, SRM University -AP, Neerukonda, 522240, India. pradyut.s@srmap.edu.in.
SRM University, Andhra Pradesh · INSRM University · INAtal Bihari Vajpayee Indian Institute of Information Technology and Management · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Photoacoustic Spectroscopy (PAS) is a potential method for the noninvasive detection of blood glucose. However random blood glucose testing can help to diagnose diabetes at an early stage and is crucial for managing and preventing complications with diabetes. In order to improve the diagnosis, control, and treatment of Diabetes Mellitus, an appropriate approach of noninvasive random blood glucose is required for glucose monitoring. A polynomial kernel-based ridge regression is proposed in this paper to detect random blood glucose accurately using PAS. Additionally, we explored the impact of the biological parameter BMI on the regulation of blood glucose, as it serves as the primary source of energy for the body's cells. The kernel function plays a pivotal role in kernel ridge regression as it enables the algorithm to capture intricate non-linear associations between input and output variables. Using a Pulsed Laser source with a wavelength of 905 nm, a noninvasive portable device has been developed to collect the Photoacoustic (PA) signal from a finger. A collection of 105 individual random blood glucose samples was obtained and their accuracy was assessed using three metrics: Root Mean Square Error (RMSE), Mean Absolute Difference (MAD), and Mean Absolute Relative Difference (MARD). The respective values for these metrics were found to be 10.94 (mg/dl), 10.15 (mg/dl), and 8.86%. The performance of the readings was evaluated through Clarke Error Grid Analysis and Bland Altman Plot, demonstrating that the obtained readings outperformed the previously reported state-of-the-art approaches. To conclude the proposed IoT-based PAS random blood glucose monitoring system using kernel-based ridge regression is reported for the first time with more accuracy.

Indexed as

Blood GlucoseDiabetes MellitusBlood Glucose Self-MonitoringHumansMonitoring, PhysiologicSpectrum AnalysisBlood Glucose

Identifiers

PMID38594267
PMCPMC11269628
OpenAlexW4394593788

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.