Evidence map›Paper›PMID 38593135›Full record

ArticlePloS one2024

Swin-cryoEM: Multi-class cryo-electron micrographs single particle mixed detection method.

Kun Fang, JinLing Wang, QingFeng Chen, Xian Feng, YouMing Qu, Jiachi Shi, Zhuomin Xu

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Kun FangHunan Meteorological Information Center, Hunan Meteorological Bureau, Changsha, Hunan, China.ORCID 0000-0001-7405-9951
JinLing WangXiangtan University& China Unicom (Hunan) Industrial Internet Co., Ltd, China Unicom (Hunan), Changsha, Hunan, China.
QingFeng ChenHunan Meteorological Information Center, Hunan Meteorological Bureau, Changsha, Hunan, China.
Xian FengHunan Meteorological Information Center, Hunan Meteorological Bureau, Changsha, Hunan, China.ORCID 0009-0008-4960-3300
YouMing QuHunan Meteorological Information Center, Hunan Meteorological Bureau, Changsha, Hunan, China.
Jiachi ShiHunan Meteorological Information Center, Hunan Meteorological Bureau, Changsha, Hunan, China.
Zhuomin XuSchool of Geography and Information Engineering, China University of Geosciences (Wuhan), Wuhan, Hubei, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cryo-electron micrograph images have various characteristics such as varying sizes, shapes, and distribution densities of individual particles, severe background noise, high levels of impurities, irregular shapes, blurred edges, and similar color to the background. How to demonstrate good adaptability in the field of image vision by picking up single particles from multiple types of cryo-electron micrographs is currently a challenge in the field of cryo-electron micrographs. This paper combines the characteristics of the MixUp hybrid enhancement algorithm, enhances the image feature information in the pre-processing stage, builds a feature perception network based on the channel self-attention mechanism in the forward network of the Swin Transformer model network, achieving adaptive adjustment of self-attention mechanism between different single particles, increasing the network's tolerance to noise, Incorporating PReLU activation function to enhance information exchange between pixel blocks of different single particles, and combining the Cross-Entropy function with the softmax function to construct a classification network based on Swin Transformer suitable for cryo-electron micrograph single particle detection model (Swin-cryoEM), achieving mixed detection of multiple types of single particles. Swin-cryoEM algorithm can better solve the problem of good adaptability in picking single particles of many types of cryo-electron micrographs, improve the accuracy and generalization ability of the single particle picking method, and provide high-quality data support for the three-dimensional reconstruction of a single particle. In this paper, ablation experiments and comparison experiments were designed to evaluate and compare Swin-cryoEM algorithms in detail and comprehensively on multiple datasets. The Average Precision is an important evaluation index of the evaluation model, and the optimal Average Precision reached 95.5% in the training stage Swin-cryoEM, and the single particle picking performance was also superior in the prediction stage. This model inherits the advantages of the Swin Transformer detection model and is superior to mainstream models such as Faster R-CNN and YOLOv5 in terms of the single particle detection capability of cryo-electron micrographs.

Indexed as

AlgorithmsElectronsCryoelectron MicroscopyImage Processing, Computer-Assisted

Identifiers

PMID38593135
PMCPMC11003668

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.