ArticleAnalytical chemistry2024
Increasing the Sensitivity of pH Glass Electrodes with Constant Potential Coulometry at Zero Current.
Article in Analytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Pulseometry: A differential readout to compensate signal drift of potentiometric probes.Science advances · 2026Article
- Symmetrical pH Electrochemical Cell Coupled to Constant Potential Coulometry for Improved Sensitivity and Precision: Part 1. Fundamental Considerations.ACS measurement science au · 2026Article
- Symmetrical pH Electrochemical Cell Coupled to Constant Potential Coulometry for Improved Sensitivity and Precision: Part 2. Submersible Probe for In Situ Measurements.ACS measurement science au · 2026Article
- Tunable Ion-Sensing Using Coulometric-Based Protocols with Permselective Nanomembranes.Analytical chemistry · 2026Article
- 3D-Printed Potentiometric Multicells for Enhanced Analytical Performance of Solid Contact Ion-Selective Electrodes.Analytical chemistry · 2025Article
- Fouling Control of Ion-Selective Electrodes (ISEs) in Aquatic and Aquacultural Environments: A Comprehensive Review.Sensors (Basel, Switzerland) · 2025Review
- Article
- Automatic titration detection method of organic matter content based on machine vision.Royal Society open science · 2025Article
- Single-Frequency Effective CapacitanceACS measurement science au · 2025Article
- Highly Sensitive Potentiometric pH Sensor Based on Polyaniline Modified Carbon Fiber Cloth for Food and Pharmaceutical Applications.ACS omega · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
It has recently become possible to increase the sensitivity of ion-selective electrodes (ISEs) by imposing a constant cell potential, allowing one to record current spikes with a capacitor placed in series in the circuit. The approach requires a transient current to pass through the measurement cell, which unfortunately may introduce measurement errors and additionally excludes the use of high-impedance indicator electrodes, such as pH glass electrodes. We present here an electronic circuit that overcomes these limitations, where the cell is measured at zero current in combination with a voltage follower, and the current spike and capacitor charging occur entirely within the instrument. The approach avoids the need for a counter electrode, and one may use any electrode useful in potentiometry regardless of its impedance. The characteristics of the circuit were found to approach ideality when evaluated with either an external potential source or an Ag/AgCl electrode. The current may be linearized and extrapolated to further reduce the measurement time. The circuit is further tested with the most common yet very challenging electrode, the pH glass electrode. A precision of 64 μpH was obtained for 0.01 pH change up to 0.05 from a reference solution. Similar pH changes were also measured reliably further away from the reference solution (0.5-0.55) and resulted in a precision of 377 μpH. The limitations of this experimental setup were explored by performing pH calibrations within the measuring range of the probe.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.