Evidence map›Paper›PMID 38592666›Full record

ArticleJournal of clinical medicine2024

Validating a Novel 2D to 3D Knee Reconstruction Method on Preoperative Total Knee Arthroplasty Patient Anatomies.

Shai Factor, Ron Gurel, Dor Dan, Guy Benkovich, Amit Sagi, Artsiom Abialevich, Vadim Benkovich

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shai FactorDivision of Orthopedic Surgery, Tel Aviv Medical Center, Faculty of Medicine, Tel Aviv University, Tel Aviv 6423906, Israel.ORCID 0000-0001-6232-3524
Ron GurelDivision of Orthopedic Surgery, Tel Aviv Medical Center, Faculty of Medicine, Tel Aviv University, Tel Aviv 6423906, Israel.ORCID 0000-0001-7861-9231
Dor DanOrthopedic Department, Meir Medical Center, Faculty of Medicine, Tel Aviv University, Tel Aviv 4428164, Israel.
Guy BenkovichOrthopedic Department, Sheba Medical Center, Faculty of Medicine, Tel Aviv University, Tel Aviv 5262000, Israel.
Amit SagiOrthopedic Department, Barzilai Medical Center, Ashkelon 78278, Israel.
Artsiom AbialevichFaculty of Health Sciences, Ben-Gurion University of the Negev, Beer Sheva 8499000, Israel.ORCID 0000-0002-4335-6002
Vadim BenkovichFaculty of Health Sciences, Ben-Gurion University of the Negev, Beer Sheva 8499000, Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAs advanced technology continues to evolve, incorporating robotics into surgical procedures has become imperative for precision and accuracy in preoperative planning. Nevertheless, the integration of three-dimensional (3D) imaging into these processes presents both financial considerations and potential patient safety concerns. This study aims to assess the accuracy of a novel 2D-to-3D knee reconstruction solution, RSIP XPlan.ai™ (RSIP Vision, Jerusalem, Israel), on preoperative total knee arthroplasty (TKA) patient anatomies.

methodsAccuracy was calculated by measuring the Root Mean Square Error (RMSE) between X-ray-based 3D bone models generated by the algorithm and corresponding CT bone segmentations (distances of each mesh vertex to the closest vertex in the second mesh). The RMSE was computed globally for each bone, locally for eight clinically relevant bony landmark regions, and along simulated bone cut contours. In addition, the accuracies of three anatomical axes were assessed by comparing angular deviations to inter- and intra-observer baseline values.

resultsThe global RMSE was 0.93 ± 0.25 mm for the femur and 0.88 ± 0.14 mm for the tibia. Local RMSE values for bony landmark regions were 0.51 ± 0.33 mm for the five femoral landmarks and 0.47 ± 0.17 mm for the three tibial landmarks. The RMSE along simulated cut contours was 0.75 ± 0.35 mm for the distal femur cut and 0.63 ± 0.27 mm for the proximal tibial cut. Anatomical axial average angular deviations were 1.89° for the trans epicondylar axis (with an inter- and intra-observer baseline of 1.43°), 1.78° for the posterior condylar axis (with a baseline of 1.71°), and 2.82° (with a baseline of 2.56°) for the medial-lateral transverse axis.

conclusionsThe study findings demonstrate promising results regarding the accuracy of XPlan.ai™ in reconstructing 3D bone models from plain-film X-rays. The observed accuracy on real-world TKA patient anatomies in anatomically relevant regions, including bony landmarks, cut contours, and axes, suggests the potential utility of this method in various clinical scenarios. Further validation studies on larger cohorts are warranted to fully assess the reliability and generalizability of our results. Nonetheless, our findings lay the groundwork for potential advancements in future robotic arthroplasty technologies, with XPlan.ai™ offering a promising alternative to conventional CT scans in certain clinical contexts.

Indexed as

2D-to-3D3D reconstructionaccuracy assessmentartificial intelligenceknee reconstructionregistrationRSIP XPlan.aitotal knee arthroplasty (TKA)

Identifiers

PMID38592666
PMCPMC10931545

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.