Evidence map›Paper›PMID 38591946›Full record

ArticleTranslational vision science & technology2024

In-Depth Retinal Sensitivity Assessment With the MP3 Type S Microperimeter: A Methods Study.

Thales A C de Guimaraes, Isabela M C de Guimaraes, Naser Ali, Angelos Kalitzeos, Michel Michaelides

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.6field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Retinal Sensitivity in KCNV2-Associated Retinopathy.Investigative ophthalmology & visual science · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Thales A C de GuimaraesUCL Institute of Ophthalmology, University College London, London, UK.
Isabela M C de GuimaraesUniversidade Sao Leopoldo Mandic, Campinas, Sao Paulo, Brazil.
Naser AliMoorfields Eye Hospital NHS Foundation Trust, London, UK.
Angelos KalitzeosUCL Institute of Ophthalmology, University College London, London, UK.
Michel MichaelidesUCL Institute of Ophthalmology, University College London, London, UK.
Moorfields Eye Hospital NHS Foundation Trust · GBFaculdade São Leopoldo Mandic · BRMoorfields Eye Hospital · GB

Funding

Wellcome Trust
6 · The paper itself

Abstract

Purpose: Retinal sensitivity is frequently listed as an end point in clinical trials, often with long working practices. The purpose of this methods study was to provide a new workflow and reduced test time for in-depth characterization of retinal sensitivity. Methods: A workflow for the MP3-S microperimeter with detailed functional characterization of the retina under photopic, mesopic, and scotopic conditions was evaluated. Grids of 32 and 28 test positions for photopic/mesopic and scotopic, respectively, were tested in 12 healthy individuals and compared with an established 68-point grid for test time, mean sensitivity (MS), and bivariate contour ellipse area (BCEA). Results: The mean test time (range; ±SD) was 10.5 minutes (8.4-14.9; ±2.0) in the 68-point grid and 4.3 minutes (3.8-5.0; ±0.4) in the 32-point grid, which was significantly different (P < 0.0001). The mean of difference in test time (±SD; 95% confidence interval) was 6.1 minutes (±2.0; 4.6-7.6). MS and BCEA were significantly correlated between grids (r = 0.89 and 0.74; P = 0.0005 and 0.014, respectively). Mean test time of subjects who underwent the full protocol (n = 4) was 2.15 hours. Conclusions: The protocol suggested herein appears highly feasible with in-depth characterization of retinal function under different testing conditions and in a short test time. Translational Relevance: The protocol described herein allows for characterization of the retina under different testing conditions and in a short test time, which is relevant due to its potential for patient prognostication and follow-up in clinical settings and also given its increasing role as a clinical trial end point.

Indexed as

RetinaClinical Trials as TopicEndpoint DeterminationHumansWorkflow

Identifiers

PMID38591946
PMCPMC11008759
OpenAlexW4394604900

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.