Evidence map›Paper›PMID 38590192›Full record

ArticleZhongguo fei ai za zhi = Chinese journal of lung cancer2024

[Analysis of Influencing Factors of Complications for CT-guided 
Percutaneous Lung Biopsy].

Xing Wang, Hong Zhang, Xun Zhang

Open access · greenAbstract readEnglish Abstract
In one paragraph

Article in Zhongguo fei ai za zhi = Chinese journal of lung cancer, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Xing WangDepartment of Radiology, Tianjin Chest Hospital, Tianjin 300051, China.
Hong ZhangDepartment of Radiology, Tianjin Chest Hospital, Tianjin 300051, China.
Xun ZhangDepartment of Thoracic Surgery, Tianjin Chest Hospital, Tianjin 300051, China.
Tianjin Chest Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundComputed tomography guided percutaneous lung biopsy (CT-PLB) is a widely used method for the diagnosis of lung lesions. However, it is invasive, and the most common complications are pneumothorax and pulmonary hemorrhage, which can be life-threatening in severe cases. Therefore, the aim of this study is to analyze the independent risk factors affecting the occurrence of different complications of CT-PLB, so as to reduce the incidence of complications.

methodsThe 605 patients with complete clinical data who underwent CT-PLB in our hospital from May 2018 to December 2019 were retrospectively analyzed. According to the location of the lesions, they were divided into subpleural group and non-subpleural group. The patients were divided into pneumothorax group, pulmonary hemorrhage group, pneumothorax with pulmonary hemorrhage group and non-pneumothorax/pulmonary hemorrhage group according to the complications. The risk factors affecting the incidence of different complications and the independent risk factors of each complication were analyzed.

resultsThe incidence of pneumothorax was 34.1%, the incidence of pulmonary hemorrhage was 28.1%, and the incidence of pneumothorax complicated with pulmonary hemorrhage was 10.8% (63 cases). The independent risk factor affecting the incidence of subpleural pneumothorax was lesion size (P=0.002). The independent risk factors affecting the occurrence of pneumothorax in the non-subpleural group were plain scan CT value (P=0.035), length of needle through lung tissue (P=0.003), and thickness of needle through chest wall (P=0.020). Independent risk factors affecting the occurrence of pulmonary hemorrhage in the non-subpleural group were length of needle through lung tissue (P<0.001), △CT value of needle travel area (P=0.001), lesion size (P=0.034) and body position (P=0.014). The independent risk factors affecting the co-occurrence of pneumothorax and pulmonary hemorrhage were the length of needle through lung tissue (P<0.001) and the △CT value of needle travel area (P<0.001).

conclusionsCT-PLB is a safe and effective diagnostic method, which of high diagnostic value for lung lesions. Selecting the appropriate puncture program can reduce complications such as pneumothorax and pulmonary hemorrhage, and improve diagnosis and treatment efficiency.

Indexed as

Lung DiseasesLung NeoplasmsPneumothoraxThoracic WallHemorrhageHumansImage-Guided BiopsyLungRetrospective StudiesRisk FactorsTomography, X-Ray ComputedBiopsyComputed tomographyLung neoplasmsPneumothoraxPulmonary hemorrhage

Identifiers

PMID38590192
PMCPMC11002188
OpenAlexW4394763807

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.