ArticleInsights into imaging2024
Reliability, costs, and radiation dose of dual-energy X-ray absorptiometry in diagnosis of radiologic sarcopenia in surgically menopausal women.
Article in Insights into imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 7 citations in OpenAlex.
- AI-driven appendicular skeletal muscle mass index (ASMI) prediction and low muscle mass detection from routine hip X-rays: a novel opportunistic case finding tool.European geriatric medicine · 2026Article
- Endplate Bone Quality Assessment for Preoperative Planning and Patient-Specific Implementation in Lumbar Spine Surgery.Journal of clinical medicine · 2026Article
- Nutritional pathways from treatment to management of sarcopenia in patients with gastric cancer: a narrative review.Korean journal of family medicine · 2026Review
- DXA-Derived Visceral and Subcutaneous Adipose Tissue and Postmenopausal Breast Cancer Mortality.Current oncology (Toronto, Ont.) · 2026Article
- Validity of DEXA-Derived Thigh Muscle Quantification Against AI-Assisted CT: Inter-Limb Asymmetry Provides Superior Agreement over Absolute Values.Journal of clinical medicine · 2026Article
- Muscle Imaging Assessments in Sarcopenia: A Statement from China National Center for Orthopedics (NCO) and the East Meets West Action Group of the European Calcified Tissue Society (ECTS).Calcified tissue international · 2025Review
- Myosteatosis: diagnostic significance and assessment by imaging approaches.Quantitative imaging in medicine and surgery · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThe aim of this study was to evaluate and compare reliability, costs, and radiation dose of dual-energy X-ray absorptiometry (DXA) to MRI and CT in measuring muscle mass for the diagnosis of sarcopenia.
methodsThirty-four consecutive DXA scans performed in surgically menopausal women from November 2019 until March 2020 were analyzed by two observers. Observers analyzed muscle mass of the lower limbs in every scan twice. Reliability was assessed by calculating inter- and intra-observer variability. Reliability from CT and MRI as well as radiation dose from CT and DXA were collected from literature. Costs for each type of scan were calculated according to the guidelines for economic evaluation of the Dutch National Health Care Institute.
resultsThe 34 participants had a median age of 58 years (IQR 53-65) and a median body mass index of 24.6 (IQR 21.7-29.7). Inter-observer variability had an intraclass correlation coefficient (ICC) of 0.997 (95% CI 0.994-0.998) with a relative variability of 0.037 ± 0.022%. Regarding intra-observer variability, observer 1 had an ICC of 0.998 (95% CI 0.996-0.999) with a relative variability of 0.019 ± 0.016% and observer 2 had an ICC of 0.997 (95% CI 0.993-0.998) with a relative variability of 0.016 ± 0.011%. DXA costs were €62, CT €77, and MRI €195. The estimated radiation dose of CT was 2.5-3.0 mSv, for DXA this was 2-4 µSv.
conclusionsDXA has lower costs and a lower radiation dose, with low inter- and intra-observer variability, compared to CT and MRI for assessing lower limb muscle mass.
trial registrationNetherlands Trial Register; NL8068. CRITICAL RELEVANCE STATEMENT: DXA is a good alternative for CT and MRI in assessing lower limb muscle mass, with lower costs and lower radiation dose, while inter-observer and intra-observer variability are low. KEY POINTS: • Screening for sarcopenia should be optimized as the population ages. • DXA outperformed CT and MRI in the measured metrics. • DXA validity should be further evaluated as an alternative to CT and MRI for sarcopenia evaluation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.