Evidence map›Paper›PMID 38589379›Full record

ArticleScientific reports2024

Concept-drifts adaptation for machine learning EEG epilepsy seizure prediction.

Edson David Pontes, Mauro Pinto, Fábio Lopes, César Teixeira

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Machine-learning methods for epilepsy diagnosis and therapeutic prevention: advances, setbacks, and opportunities.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2026
    Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Edson David PontesDepartment of Informatics Engineering, CISUC, University of Coimbra, Coimbra, Portugal. edpontes@dei.uc.pt.
Mauro PintoDepartment of Informatics Engineering, CISUC, University of Coimbra, Coimbra, Portugal.
Fábio LopesDepartment of Informatics Engineering, CISUC, University of Coimbra, Coimbra, Portugal.
César TeixeiraDepartment of Informatics Engineering, CISUC, University of Coimbra, Coimbra, Portugal.

Funding

Centre for Informatics and Systems of the University of Coimbra UID/CEC/00326/2020project RECoD PTDC/EEI-EEE/5788/2020
6 · The paper itself

Abstract

Seizure prediction remains a challenge, with approximately 30% of patients unresponsive to conventional treatments. Addressing this issue is crucial for improving patients' quality of life, as timely intervention can mitigate the impact of seizures. In this research field, it is critical to identify the preictal interval, the transition from regular brain activity to a seizure. While previous studies have explored various Electroencephalogram (EEG) based methodologies for prediction, few have been clinically applicable. Recent studies have underlined the dynamic nature of EEG data, characterised by data changes with time, known as concept drifts, highlighting the need for automated methods to detect and adapt to these changes. In this study, we investigate the effectiveness of automatic concept drift adaptation methods in seizure prediction. Three patient-specific seizure prediction approaches with a 10-minute prediction horizon are compared: a seizure prediction algorithm incorporating a window adjustment method by optimising performance with Support Vector Machines (Backwards-Landmark Window), a seizure prediction algorithm incorporating a data-batch (seizures) selection method using a logistic regression (Seizure-batch Regression), and a seizure prediction algorithm with a dynamic integration of classifiers (Dynamic Weighted Ensemble). These methods incorporate a retraining process after each seizure and use a combination of univariate linear features and SVM classifiers. The Firing Power was used as a post-processing technique to generate alarms before seizures. These methodologies were compared with a control approach based on the typical machine learning pipeline, considering a group of 37 patients with Temporal Lobe Epilepsy from the EPILEPSIAE database. The best-performing approach (Backwards-Landmark Window) achieved results of 0.75 ± 0.33 for sensitivity and 1.03 ± 1.00 for false positive rate per hour. This new strategy performed above chance for 89% of patients with the surrogate predictor, whereas the control approach only validated 46%.

Indexed as

EpilepsyQuality of LifeAlgorithmsElectroencephalographyHumansMachine LearningSeizuresSupport Vector Machine

Identifiers

PMID38589379
PMCPMC11001609

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.