Evidence map›Paper›PMID 38587669›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Spacer rotation technique allows precise evaluation of gap balance in total knee arthroplasty.

Georg Matziolis, Frank Layher, Sophia Vogt, Leah Bergner, Georgi Wassilew, Julia Kirschberg

Abstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Georg MatziolisOrthopaedic Department, University Hospital Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany. g.matziolis@waldkliniken-eisenberg.de.ORCID http://orcid.org/0000-0002-5105-5875
Frank LayherOrthopaedic Department, University Hospital Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
Sophia VogtOrthopaedic Department, University Hospital Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
Leah BergnerOrthopaedic Department, University Hospital Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
Georgi WassilewCenter for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, 17475, Greifswald, Germany.
Julia KirschbergOrthopaedic Department, University Hospital Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The symmetry of the flexion and extension gap influences the functional and long-term outcome after total knee arthroplasty (TKA). Most surgeons check it by applying varus and valgus stress using spacers. This technique has limited accuracy and could be easily extended by rotational movement of the spacer. The objective was to determine the detection threshold and interobserver reliability of this technique. In an in vitro setting with a human cadaveric knee, gap asymmetries were simulated by different medially and laterally applied forces. Using an optical measurement system, the pivot point of the spacer was calculated as a function of the gap symmetry in the first part of the experiment. In the second part, the detection threshold and interobserver reliability of 4 surgeons were determined. For this purpose, gap asymmetries were adjusted to between 0 and 120N in a blinded trial. With a symmetrical gap, the centre of rotation of the spacer was located in the centre of the tibia. With increasing gap asymmetry, the centre of rotation of the spacer shifted to the tight side. This shift was approximately linearly dependent on the force difference. A perfectly balanced gap was detected by the examiners in 50% of the cases. From a force difference of 40N, all examiners identified the gap asymmetry in all cases (ICC = 1.0). The method of spacer rotation described is suitable for reliably detecting gap differences at ≥ 40N, independently of the examiner.

Indexed as

Arthroplasty, Replacement, KneeCadaverBiomechanical PhenomenaHumansKnee JointKnee ProsthesisObserver VariationRange of Motion, ArticularRotationAsymmetryExtension gapFlexion gapSpacerSymmetryTotal knee arthroplasty

Identifiers

PMID38587669
PMCPMC11093784

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked