Where is the gap after a 90 W/4 s very-high-power short-duration ablation of atrial fibrillation?: Association with the left atrial-pulmonary vein voltage and wall thickness.

Moyuru Hirata, Koichi Nagashima, Ryuta Watanabe, Yuji Wakamatsu, Shu Hirata, Sayaka Kurokawa, Yasuo Okumura

Abstract read
In one paragraph

Article in Journal of arrhythmia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Revisiting low-voltage interpretation: Chamber-specific relationships between myocardial wall thickness and omnipolar voltage.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Moyuru HirataDivision of Cardiology, Department of Medicine Nihon University School of Medicine Tokyo Japan.ORCID https://orcid.org/0000-0003-2701-486X
Koichi NagashimaDivision of Cardiology, Department of Medicine Nihon University School of Medicine Tokyo Japan.ORCID https://orcid.org/0000-0003-2326-225X
Ryuta WatanabeDivision of Cardiology, Department of Medicine Nihon University School of Medicine Tokyo Japan.ORCID https://orcid.org/0000-0003-2664-7139
Yuji WakamatsuDivision of Cardiology, Department of Medicine Nihon University School of Medicine Tokyo Japan.ORCID https://orcid.org/0000-0002-1540-8514
Shu HirataDivision of Cardiology, Department of Medicine Nihon University School of Medicine Tokyo Japan.ORCID https://orcid.org/0000-0003-0226-466X
Sayaka KurokawaDivision of Cardiology, Department of Medicine Nihon University School of Medicine Tokyo Japan.
Yasuo OkumuraDivision of Cardiology, Department of Medicine Nihon University School of Medicine Tokyo Japan.ORCID https://orcid.org/0000-0002-2960-4241

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Although pulmonary vein isolation (PVI) for atrial fibrillation (AF) utilizing radiofrequency (RF) applications with a very high-power and short-duration (vHPSD) has shortened the procedure time, the determinants of pulmonary vein (PV) gaps in the first-pass PVI and acute PV reconnections are unclear. Methods: An extensive encircling PVI was performed with the QDOT MICRO catheter with a vHPSD (90 W-4 s) in 30 patients with AF (19 men, 64 ± 10 years). The association of the PV gap sites (first-pass PVI failure, acute PV reconnections [spontaneous reconnections or dormant conduction provoked by adenosine triphosphate] or both) with the left atrial (LA) wall thickness and LA bipolar voltage on the PVI line and ablation-related parameters were assessed. Results: PV gaps were observed in 29 (6%) of 480 segments (16 segments per patient) in 17 patients (56%). The PV gaps were associated with the LA wall thickness, bipolar voltage, and the number of RF points (LA wall thickness, 2.5 ± 0.5 vs. 1.9 ± 0.4 mm, Conclusions: The LA voltage and wall thickness on the PV-encircling ablation line were highly associated with PV gaps using the 90 W/4 s-vHPSD ablation.

Indexed as

atrial fibrillationvery high‐power short‐duration ablationvoltageswall thickness

Identifiers

PMID38586851
PMCPMC10995583

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.