ArticleCureus2024
The False-Positive Rate of Synovial Fluid Culture at a Single Clinical Laboratory Using Culture Bottles.
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07718386 (The Diagnosis Dilemma), which is not on this map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Diagnosis Dilemma: Efficacy of Serum ESR, CRP, Synovial Leucocyte Esterase Dipstick Test in the Diagnosis of Chronic Infection in Total Joint Arthroplasty.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction Synovial fluid (SF) cultures can yield false-positive or negative results when diagnosing periprosthetic joint infection (PJI). False-positives may arise during sample collection or from laboratory contamination. Understanding false-positive SF culture rates is crucial for interpreting PJI laboratory data, yet clinical laboratories rarely report these rates. This study aimed to define the false-positive SF culture rate at a major specialized clinical laboratory. Methods This study retrospectively analyzed prospectively collected data at a single clinical laboratory that receives SF for clinical testing for PJI. A total of 180,317 periprosthetic SF samples from the hip, knee, and shoulder were identified from January 2016 to December 2023, which met the inclusion criteria for this study. Samples were classified by both a modified 2018 International Consensus Meeting (ICM) score and an inflammation score that combined the SF-C-reactive protein, alpha-defensin, SF-white blood cell count, and SF-polymorphonuclear% into one standardized metric. Logistic regression was utilized to evaluate the impact of various collection-based characteristics on culture positivity, including inflammation biomarkers, the source joint, quality control metrics, and days of specimen transport to the laboratory. SF culture false-positivity was calculated based on the ICM category of "not-infected" or low inflammation score. Results Overall, 13.3% (23,974/180,317) of the samples were associated with a positive culture result: 12.5% for knee samples, 20.3% for hip samples, and 14.7% for shoulder samples. The false-positive SF culture rate among 131,949 samples classified as "not-infected" by the modified 2018 ICM definition was 0.47% (95%CI: 0.43 to 0.51%). Stratification by joint revealed a false-positive rate of 0.34% (95%CI: 0.31 to 0.38%) for knee samples, 1.24% (95%CI: 1.05 to 1.45%) for hip samples, and 3.02% (95%CI: 2.40 to 3.80%) for shoulder samples, with p < 0.0001 for all comparisons. The false-positive SF culture rate among 90,156 samples, representing half of all samples with the lowest standardized inflammation scores, was 0.47% (95%CI: 0.43 to 0.52%). Stratification by joint revealed a false-positive rate of 0.33% (95%CI: 0.29 to 0.37%) for knee samples, 1.45% (95%CI: 1.19 to 1.77%) for hip samples, and 3.09% (95%CI: 2.41 to 3.95%) for shoulder samples, with p<0.0001 for all comparisons. Multivariate logistic regression demonstrated the joint source (hip, shoulder) and poor sample quality as collection-based factors associated with a false-positive culture. Evaluation of a cohort of samples selected to minimize collection-based causes of false-positive culture demonstrated a false-positive rate of 0.30%, representing the ceiling limit for laboratory-based SF culture false-positivity. Conclusions This study utilizes two methods to estimate the false-positive SF culture rate at a single specialized clinical laboratory, demonstrating an overall false-positive rate of approximately 0.5%. Stratification of samples by source joint demonstrated that periprosthetic SF from the shoulder and hip have a substantially higher false-positive culture rate than that of the knee. The lowest false-positive SF culture rate (0.30%) was observed among samples from the knee-passing quality control. Culture positivity due to contamination at this specific laboratory is less than 0.30% because all specimens undergo identical processing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.