Analyzing the Accuracy of Digital Sizing on Long-Leg Alignment X-rays by Using a 1-Inch Ball Bearing: A Cheap and Effective Method.

Trey D VanAken, Daniel Joiner, Lauryn Boggs, Andrew Robinson, Nahel Haji, Rahul Vaidya

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Trey D VanAkenDepartment of Orthopaedic Surgery, Wayne State University Detroit Medical Center, Detroit, USA.
Daniel JoinerDepartment of Orthopaedic Surgery, Wayne State University Detroit Medical Center, Detroit, USA.
Lauryn BoggsDepartment of Orthopaedic Surgery, Wayne State University Detroit Medical Center, Detroit, USA.
Andrew RobinsonDepartment of Orthopaedic Surgery, Wayne State University Detroit Medical Center, Detroit, USA.
Nahel HajiDepartment of Orthopaedic Surgery, Wayne State University Detroit Medical Center, Detroit, USA.
Rahul VaidyaDepartment of Orthopaedic Surgery, Wayne State University Detroit Medical Center, Detroit, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and objective Sizing on digital films is important for implants and planning deformity correction. CT is the most accurate digital measurement method. We use a 1-inch ball bearing (cost: $1) to size our long-leg standing films (LLSFs) when planning deformity correction. In this study, we aimed to assess the accuracy of digital measurements calibrated by this method. Methods We conducted An IRB-approved study involving 25 patients having both an LLSF with a 1-inch ball bearing taped to the inner mid-thigh and a CT scanogram. The longest distance in the axial cut of the bilateral ankle, knee, and femoral heads of the CT images were compared to the same anatomic locations on LLSFs calibrated with the ball bearing using the online digital planning software DetroitBonesetter (DBS) and measurements from our Picture Archiving Communication Software (PACS). Five observers performed each measurement. Results The average measurement differences between the gold standard CT scan and LLSFs calibrated with DBS were as follows: 0.110 ± 0.432 mm (femoral head); 2.173 ± 0.0619 mm (knee); and 3.671 ± 0.30 mm (ankle). In PACS, they were as follows: 5.470 ± 0.381 mm (femoral head); 6.248 ± 0.712 mm (knee); and 1.806 ± 0.548 mm (ankle). The intraclass correlation coefficient for 600 measurements by five observers was 0.972. Conclusions The $1 ball-bearing sizing on DBS using LLSFs provides accuracy to <1 mm for the femoral head, 2 mm at the knee, and 3.7 mm at the ankle. It was significantly better than the PACS system for both the femoral head and knee (<0.001), while PACS was better at the ankle (<0.001).

Indexed as

ball bearingcomputerized tomographyct scanogramdigital planningdigital sizingdigital templatinglong-leg radiographslong leg standing alignment films

Identifiers

PMID38586638
PMCPMC10998698

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.