Evidence map›Paper›PMID 38584395›Full record

ArticleEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2024

Application of a circular-shaped pulsed field ablation catheter with magnetic sensors for pulmonary vein isolation: a multi-centre clinical study report.

Yan Wang, Heng Li Lai, Qi Chen, Hao Liu, Qi Ming Liu, Wei Bin Huang, Yu Tao, Qingmei Xiong, Ning Zhou, Chunxia Zhao and 3 more

Open access · hybridAbstract readMulticenter Study
In one paragraph

Article in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Beyond speed: why "skin-to-skin" time should not define quality in atrial fibrillation ablation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
    Review
  4. Efficacy and safety of a novel pulsed field ablation system in paroxysmal atrial fibrillation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
    Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 6 institutions in 1 country.

Yan WangDivision of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China.ORCID 0000-0002-6976-2412
Heng Li LaiDivision of Cardiology, Jiangxi Provincial People's Hospital, Nanchang, China.ORCID 0000-0002-7182-0722
Qi ChenDepartment of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, Nanchang, China.ORCID 0000-0002-0393-5296
Hao LiuDivision of Cardiology, The Second Affiliated Hospital of Guangxi Medical University, Nanning, China.ORCID 0009-0006-7699-7427
Qi Ming LiuDivision of Cardiology, Xiamen University Affiliated Zhongshan Hospital, Xiamen, China.ORCID 0000-0002-5213-2668
Wei Bin HuangDivision of Cardiology, The Second Xiangya Hospital of Central South University, Changsha, China.ORCID 0009-0009-3634-9726
Yu TaoDivision of Cardiology, Jiangxi Provincial People's Hospital, Nanchang, China.
Qingmei XiongDepartment of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, Nanchang, China.ORCID 0000-0001-8423-635X
Ning ZhouDivision of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China.ORCID 0000-0003-0863-3091
Chunxia ZhaoDivision of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China.ORCID 0009-0000-9010-0037
Jie QiuDivision of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China.
Ziqin XuDivision of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China.
Dao Wen WangDivision of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue 1095#, 430030 Wuhan, China.ORCID 0000-0002-9774-3980
Tongji Hospital · CNJiangxi Provincial People's Hospital · CNNanchang University · CNCentral South University · CNGuangxi Medical University · CNZhongshan Hospital of Xiamen University · CN

Funding

Sichuan Jinjiang Electronic Medical Device Technology Co., Ltd, Chengdu, China
6 · The paper itself

Abstract

aimsA few studies have reported the effect and safety of pulsed field ablation (PFA) catheters for ablating atrial fibrillation (AF), which were mainly based on basket-shaped or flower-shaped designs. However, the clinical application of a circular-shaped multi-electrode catheter with magnetic sensors is very limited. To study the efficacy and safety of a PFA system in patients with paroxysmal AF using a circular-shaped multi-electrode catheter equipped with magnetic sensors for pulmonary vein isolation (PVI). METHODS AND

resultsA novel proprietary bipolar PFA system was used for PVI, which utilized a circular-shaped multi-electrode catheter with magnetic sensors and allowed for three-dimensional model reconstruction, mapping, and ablation in one map. To evaluate the efficacy, efficiency, and safety of this PFA system, a prospective, multi-centre, single-armed, pre-market clinical study was performed. From July 2021 to December 2022, 151 patients with paroxysmal AF were included and underwent PVI. The study examined procedure time, immediate success rate, procedural success rate at 12 months, and relevant complications. In all 151 patients, all the pulmonary veins were acutely isolated using the studied system. Pulsed field ablation delivery was 78.4 ± 41.8 times and 31.3 ± 16.7 ms per patient. Skin-to-skin procedure time was 74.2 ± 29.8 min, and fluoroscopy time was 13.1 ± 7.6 min. The initial 11 (7.2%) cases underwent procedures with deep sedation anaesthesia, and the following cases underwent local anaesthesia. In the initial 11 cases, 4 cases (36.4%) presented transient vagal responses, and the rest were all successfully preventatively treated with atropine injection and rapid fluid infusion. No severe complications were found during or after the procedure. During follow-up, 3 cases experienced atrial flutter, and 11 cases had AF recurrence. The estimated 12-month Kaplan-Meier of freedom from arrhythmia was 88.4%.

conclusionThe PFA system, comprised of a circular PFA catheter with magnetic sensors, could rapidly achieve PVI under three-dimensional guidance and demonstrated excellent safety with comparable effects.

Indexed as

Atrial FibrillationCatheter AblationPulmonary VeinsCathetersHumansMagnetic PhenomenaProspective StudiesRecurrenceTreatment OutcomeAtrial fibrillationCatheter ablationElectroporationPulmonary vein isolationPulsed field ablation

Identifiers

PMID38584395
PMCPMC10999647
OpenAlexW4394573814

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.