Evidence map›Paper›PMID 38584379›Full record

ArticleJournal of chest surgery2024

Change in Pulmonary Arteries after Modified Blalock-Taussig Shunt Procedure: Analysis Based on Computed Tomography.

Sangjun Lee, Jae Gun Kwak, Woong-Han Kim

Open access · diamondAbstract read
In one paragraph

Article in Journal of chest surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Sangjun LeeDepartment of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0001-6710-3563
Jae Gun KwakDepartment of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0002-6375-1210
Woong-Han KimDepartment of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0003-2837-7929
Seoul National University Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Although the modified Blalock-Taussig shunt remains the mainstay method of palliation for augmenting pulmonary blood flow in various congenital heart diseases, the shunt must be carefully designed to achieve the best outcomes. This study investigated the effect of shunt configuration on pulmonary artery growth and growth discrepancy. Methods: Twenty patients with successful modified Blalock-Taussig shunt takedown were analyzed. Pulmonary artery and shunt characteristics were obtained using computed tomography scans. Differences in the baseline and follow-up diameter ratios and growth in the ipsilateral and contralateral arteries were calculated. The angle between the shunt and pulmonary artery, as well as the distance from the main pulmonary artery bifurcation, were measured. Correlations between pulmonary arteries and shunt configurations were analyzed. Results: The median interval time between shunt placement and takedown was 154.5 days (interquartile range, 113.25-276.25 days). Follow-up values of the ipsilateral-to-contralateral pulmonary artery diameter ratio showed no significant correlation with the shunt angle (ρ=0.429, p=0.126) or distance (ρ=0.110, p=0.645). The shunt angle and distance from the main pulmonary bifurcation showed no significant correlation (ρ=-0.373, p=0.189). Pulmonary artery growth was negatively correlated with shunt angle (ipsilateral, ρ=-0.565 and p=0.035; contralateral, ρ=-0.578 and p=0.030), but not with distance (ipsilateral, ρ=-0.065 and p=0.786; contralateral, ρ=-0.130 and p=0.586). Conclusion: Shunt configuration had no significant effect on growth imbalance. The angle and distance of the shunt showed no significant correlation with each other. A more vertical shunt was associated with significant pulmonary artery growth. We suggest a more vertical graft design for improved pulmonary artery growth.

Indexed as

Computed tomographyModified Blalock-Taussig shuntPulmonary artery growthShunt angleShunt configuration

Identifiers

PMID38584379
PMCPMC11089062
OpenAlexW4394575393

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.