ArticleOphthalmology and therapy2024
Dynamic Changes of Capsular-Intraocular Lens Adhesion in Plate-Haptic Hydrophilic and Loop-Haptic Hydrophobic Eyes.
Article in Ophthalmology and therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Long-term visual outcomes and rotational stability of two diffractive toric intraocular lenses with different design combinations in cataract patients with long axial length.Frontiers in medicine · 2026Article
- Cataract: Surgery first - is there still room for basic research?Advances in ophthalmology practice and researchReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
introductionThe aim of this work is to investigate the dynamic changes of capsular-intraocular lens (IOL) adhesion in plate-haptic hydrophilic and loop-haptic hydrophobic eyes.
methodsCataract eyes that met the inclusion criteria were randomly assigned to receive implantation of a plate-haptic hydrophilic or loop-haptic IOL. The anterior capsular adhesion, posterior capsular adhesion, and the configurations of the capsular bend were evaluated using swept-source optical coherence tomography at 1 day, 1 week, 1 month, and 3 months postoperatively.
resultsIn total, 66 eyes of 66 patients were eligible for the analysis: 33 in the plate-haptic group and 33 in the loop-haptic group. The contact between the anterior capsule and IOL in the plate-haptic group was earlier than that in the loop-haptic group upon comparing the measurements taken at 1 day and 1 week (p = 0.001, p = 0.003, respectively). The complete attachment of the posterior capsule and IOL in the plate-haptic group was significantly greater at 1 week, 1 month, and 3 months (p = 0.001, p = 0.000, p = 0.001, respectively). The capsular bend index of the plate-haptic group was significantly greater than that of the loop-haptic group at each time points except at 1 day (p = 0.007, p = 0.049, p = 0.005, respectively). Furthermore, a new type of capsular bend, "cocked adhesion," was observed in the plate-haptic eyes.
conclusionsThe plate-haptic IOL demonstrated excellent capsular adhesion compared to the loop-haptic IOL, which was probably attributed to haptic compressibility. A special cocked configuration of the capsular bend in plate-haptic IOL was observed for the first time. Further studies are warranted to confirm the effect of the new type of capsular bend.